M68MULTILINK08 Freescale Semiconductor, M68MULTILINK08 Datasheet - Page 49

PROGRAMMER LOW COST 68HC908

M68MULTILINK08

Manufacturer Part Number
M68MULTILINK08
Description
PROGRAMMER LOW COST 68HC908
Manufacturer
Freescale Semiconductor
Type
In Circuit Debuggerr
Datasheet

Specifications of M68MULTILINK08

Contents
In-Circuit Programmer, Emulator, Debugger, CodeWarrior Dev. Studio for HC08, Power Supply
For Use With/related Products
68HC908 FLASH MCUs
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
P&E
MON08 Multilink User Manual
Microcomputer
Systems, Inc.
1 – Device echoed some security bytes:
2 – Device echoed all security bytes:
3 – Device signaled monitor mode with a break:
analyzing the reset of the status bits.
The monitor resident in a 68HC08 device automatically echoes every
incoming character when it is in monitor mode. A valid character
transmitted from the PC should be echoed once by the loopback circuitry
on the board and once by the monitor of the target processor itself. This
status indicates whether or not the second echoed character from the
monitor response was received when one of the security bytes was
transmitted. If the status is ‘N’, which indicates that the character was not
received, or not received properly, it is most likely due to one of the
following reasons:
If this status bit responded with an ‘N’, you must correct this before
analyzing the reset of the status bits.
In order to pass security, the software must send 8 security bytes to the
processor. The processor should echo each of these eight bytes twice. If all
8 bytes did not get the proper two-byte echo, this flag will be ‘N’. Reasons
for this include:
Once the processor has properly received the 8 bytes from the PC software
to complete its security check, it should transmit a break character to the
PC signaling entry into monitor mode. This break should be sent regardless
of whether the security check was successfully passed. If a break was not
received from the processor, this flag will be ‘N’. Reasons for this include:
Freescale Semiconductor, Inc.
1. The baud rate specified was incorrect.
2. The part did not start the monitor mode security check on reset.
Signals to force monitor mode may be incorrect.
3. No Power to the ICS.
1. The part did not start the monitor mode security check on reset.
Signals to force monitor mode may be incorrect.
2. The baud rate specified was incorrect.
3. The processor was not reset properly. Check the “Target Hardware
Type” and if you are connecting to a class II board, check the “MON08
cable communication connections type” in the “advanced settings”
dialog.
1. The baud rate specified was incorrect.
2. The processor was not reset properly. Check the “Target Hardware
For More Information On This Product,
Go to: www.freescale.com
MON08 MULTILINK
49

Related parts for M68MULTILINK08