H5S-WB2 Omron, H5S-WB2 Datasheet - Page 13

TIMER DIGITAL WEEKLY 100-240VAC

H5S-WB2

Manufacturer Part Number
H5S-WB2
Description
TIMER DIGITAL WEEKLY 100-240VAC
Manufacturer
Omron
Series
H5Sr
Datasheets

Specifications of H5S-WB2

Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Product
Digital Timer
Termination Style
Screw
No. Of Digits / Alpha
2
Meter Function
Counter
Supply Voltage Max
240VAC
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Z2504
■ EN/IEC Standards
• The insulation system between the power supply circuit and input-
• Use crimp type cable lug terminals with insulating sleeves for
• Be sure to mount a surface-mounting model (H5S-@FA@/-@FB@)
Basic Use
Prior to Using
Before setting the parameters necessary for each operation, the operation of each circuit (output) must be determined. Begin by setting initial
setting mode as required.
Note: Pull the front cover open
output terminals provides basic insulation.
Therefore connect the output terminals only to circuits without
exposed conductive parts. If a connection to a Safety Extra Low
Voltage (SELV) circuit is desired, supplementary insulation must be
provided.
wiring.
in an enclosure.
Open the front cover.
OUT
with your fingertips.
AUTO
OFF
SUN
ON
OUT1 OUT2
MON
TUE
WED
THU
Y
FRI
M
h
SAT
m/PLS
D
HOLIDA
RUN
P1
P2
WR
Note: Use the tip of a ball-point
Timer operation
operation of each circuit
Determine and set the
TIMER
PULSE
pen, or other sharp
instrument, to make the
settings.
AUTO
OFF
SUN
ON
OUT
OUT1 OUT2
MON
(output).
TUE
TIME ADJ
Pulse operation
WED
YEAR CYCLE CLEAR
TEST
THU
Y
FRI
M
h
• The relationship between load current and ambient air temperature
• Control system:
SAT
m/PLS
D
is shown by the range below for 2-circuit models.
If wires with a temperature rating of 105 °C or higher are used, refer
to the derating curve in Specifications on page 3.
Types of automatic operation:
Protective class:
Rated impulse withstand voltage: 2,500 V AC
Ball-pressure test temperature (enclosure material): 125°C
HOLIDA
40
30
20
10
0
WRI
10
R
0
Set as necessary:
Note: These
settings are
not required
to use the
basic Time
Switch
functions.
20
Ambient temperature (°C)
40
The Initial Setting mode must be set to
use the following functions.
Common to all models:
• Next Operation Display Switching
Weekly models:
• Time Counter/Total Counter Display
• Time Adjustment Input
• Manual Operation on Recovery from
• Bank Switching
Yearly models:
• Time Counter/Total Counter Display
• Time Adjustment Input (See note.)
• Manual Operation on Recovery from
• Season Switching
• Date Format Selection
• Summer Time (DST) Adjustment
Note: 2-circuit models only
Power Failure
(See note.)
Power Failure (See note.)
55 60
Set initial setting mode.
Electronic
Weekly models - Type 1 BSTU
Yearly models - Type 2 BSTU
Class 0
For details, refer to Using
Advanced Functions on page
23.
80
H5S
13