H5S-WB2 Omron, H5S-WB2 Datasheet - Page 20

TIMER DIGITAL WEEKLY 100-240VAC

H5S-WB2

Manufacturer Part Number
H5S-WB2
Description
TIMER DIGITAL WEEKLY 100-240VAC
Manufacturer
Omron
Series
H5Sr
Datasheets

Specifications of H5S-WB2

Supply Voltage
100 V to 240 V
Current Rating (max)
100 mA
Product
Digital Timer
Termination Style
Screw
No. Of Digits / Alpha
2
Meter Function
Counter
Supply Voltage Max
240VAC
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
Z2504
Convenient Functions
Setting Temporary Holidays (Weekly)
Temporary holidays (non-operating days) can be easily set.
Because the setting is automatically cleared after the set holiday has
passed, temporary holidays are easily set without changing other
settings, including those of the Output ON/OFF Switches.
Weekly, 2 Circuits
Example: Friday and Saturday in the current week are set as
1. Press
2. Turn OFF the bars (
3. Press
Note:
• Any day in the 7-day period starting from the current day can be
• All ON operations are cancelled on the holiday.
• The set holidays are valid for all the output circuits.
• You must be in RUN mode to enter to holiday setting mode.
• If the current day of the week is changed, the holiday settings will
• Press
set as a holiday.
The setting is automatically cleared after the set holiday has
passed.
be cleared.
mode. If you do nothing for 30 s, the Time Switch will
automatically return to RUN mode.
RUN mode.
(The Time Switch enters holiday
setting mode.)
positions of the days to be set as
holidays.
Bar ON: Operating day
Bar OFF: Holiday
After “hday” is displayed for
approximately 1 s, the Time Switch
returns to RUN mode.
HOLIDAY
HOLIDAY
WRITE
holidays (non-operating days).
The Time Switch then operates according to the ordinary
(previous) settings from the following week onward.
to enter the setting.
for 2 s in holiday setting mode to return to RUN
for 2 s or more in
) at the
Shaded portion indicates
blinking of the indicator.
SUN MON TUE WED THU FRI SAT
SUN MON TUE WED THU FRI SAT
Setting Temporary Holidays (Yearly)
Temporary* holidays (non-operating days) can be set simply by
specifying dates. The holidays will be OFF in both the weekly and
yearly programs. Because the setting is automatically cleared after
the set holiday has passed, temporary holidays are easily set without
changing other settings, including those of the Output ON/OFF
Switches.
* Annual holidays can also be set.
Yearly, 2 Circuits
Example: The days from April 29 to May 7 in 2006 are set as
1. Press
2. Specify the start date of holidays
<Example> If the current year is 2006,
3. Press
4. Press
5. Press
*1 If one or more programs have already been set, the display starts showing
*2 Holding down the date-setting keys rapidly advances the value.
Note:
• Any date between the current date and December 31 in the year
• The setting is automatically cleared after the set holiday has
• Repeat steps 2 to 4 to make other settings.
• Both the start and end dates of holidays must be set. The
• You must be in RUN mode to enter to holiday setting mode.
• If the current date is changed, the holiday settings will be cleared.
• When you specify the year, be sure to set the end date so that it is
• Press
after the following year can be specified as a holiday.
passed (unless the year is set to --).
maximum number of holidays that can be set is 16.
after the start date.
mode. If you do nothing for 30 s, the Time Switch will
automatically return to RUN mode.
the set programs.
To add another program, press
displayed.
Pressing
RUN mode. *1
(The Time Switch enters holiday
setting mode.)
using
The year is displayed in the following
order by pressing
be set from the current year to the
next two years.)
If the year is set to --, the holiday
setting is executed every year.
In the same manner, specify the end
date of holidays using
If the starting year has been set to
“--“, the ending year cannot be set.
D
. *2
HOLIDAY
HOLIDAY
Y
WRITE
WRITE
HOLIDAY
holidays (non-operating days). The Time Switch then
operates according to the ordinary (previous) settings
from the following year onward.
the displayed year changes
as follows.
06→07→08→--→06→
,
decrements the value of the key that was last pressed.
M
.
to enter the settings.
and
for 2 s in holiday setting mode to return to RUN
Yearly, 4 Circuits
for 2 s or more in
for 2 s or more to return to RUN mode.
Y
D
. (The year can
. *2
Y
,
WRITE
M
and
repeatedly until “--.--“ is
Shaded portion indicates
blinking of the indicator.
H5S