H8GN-AD DC24 Omron, H8GN-AD DC24 Datasheet

no-image

H8GN-AD DC24

Manufacturer Part Number
H8GN-AD DC24
Description
TIMER/COUNTER 1/32DIN 24VDC
Manufacturer
Omron
Series
H8GNr
Datasheet

Specifications of H8GN-AD DC24

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H8GN-ADDC24
H8GNADDC24
A DIN 48 × 24 Preset Counter.
Compact, Yet Equipped with
Communication.
• Only 48 × 24 × 83 mm (W × H × D)
• Switch between 4-digit preset counter and 4-digit timer opera-
• While using the preset counter, it is possible to switch the dis-
• Built-in prescaling for counter operation.
• ON/OFF-duty adjustable flicker mode that can be used to per-
• SV can be changed using front panel keys to any of four values
• Water-proof structure to NEMA4X/IP66.
• Conforms to UL, CSA, and IEC safety standards as well as CE
Model Number Structure
■ Model Number Legend
1. Supply Voltage
Ordering Information
■ List of Models
H8GN-AD-@
24 VDC
tion.
play to monitor the totalizing count value (8 digits).
form cyclic control is available for timer operation.
preset in SV-banks.
Marking.
Preset Counter/Timer (48 × 24)
H8GN
D:
24 VDC
Supply voltage
Refer to Safety Precautions on page 7.
1
2
Contact output (SPDT)
Output
H8GN-AD
2. Communications Output Type
None: Communications not supported
FLK: RS-485
No communications
Communications
H8GN-AD-FLK
CSM_H8GN_DS_E_3_1
RS-485
1

Related parts for H8GN-AD DC24

H8GN-AD DC24 Summary of contents

Page 1

... Refer to Safety Precautions on page 7. Model Number Structure ■ Model Number Legend H8GN-AD Supply Voltage D: 24 VDC Ordering Information ■ List of Models Supply voltage 24 VDC Contact output (SPDT) 2. Communications Output Type None: Communications not supported FLK: RS-485 Output No communications H8GN-AD CSM_H8GN_DS_E_3_1 Communications RS-485 H8GN-AD-FLK 1 ...

Page 2

... The maximum counting speed will also be reduced to about half when the up/down mode is selected. Start, gate, and reset 1 kΩ max. (Approx runoff current at 0 Ω) Short-circuit (ON) impedance: Short-circuit (ON) residual voltage:2 VDC max. Open (OFF) impedance: 100 kΩ min. Applied voltage: 30 VDC max. H8GN 2 ...

Page 3

... UL508, CSA C22.2 No.14 Conforms to EN61010-1/IEC61010-1 (Pollution degree 2/overvoltage category II) Conforms to VDE0106/P 100 (Finger Protection) Rear section: Gray smoke; Front section: N1.5 (black) Panel surface: IP66 and NEMA Type 4X (indoors) Rear case: IP20 Terminal block: IP20 Approx H8GN 3 ...

Page 4

... Retry function Not supported. Communications buffer 40 bytes Reading and writing from H8GN Reading present value and totalizing count value; reading/writing preset and set values; switching be- tween SV-banks; switching between communications write-enabled/write-prohibited; reading/writing other initial and advanced function setting parameters Note: The baud rate, data bit length, stop bit length, and vertical parity can be individually set using the communications setting level. ...

Page 5

... The RST indicator is lit during resetting. • Prohibits timing operation. • Output made according to the output mode setting when the set value is reached. ■ Wiring Use the following type of crimp terminals for M3 screw. H8GN (Basic insulation) 5.8 mm max. 5.8 mm max. ...

Page 6

... No. 2 Display Displays set value or set value of the parameter. Displays the rightmost 4 digits of the count value (8 digits) when the H8GN is used as a totalizing counter. (Zeros suppressed) Up/Reset Key Each press of this key increases values displayed on the No. 2 display. Hold down this key continuously to increase values quickly ...

Page 7

... Doing so may result in electric shock, fire, or malfunction. Other Precautions • Store at the specified temperature. If the H8GN has been stored at a temperature of less than −10°C, allow the H8GN to stand at room temperature for at least 3 hours before use. • Use the product within the ratings specified for vibration, shock, submerging in water, and exposure to oil. • ...

Page 8

... When the H8GN is used with power start in F mode (i.e., accumula- tive operation with output on hold), there will be a timer error (approx- imately 100 ms each time the H8GN is turned ON) due to the characteristics of the internal circuitry. Use the H8GN with signal start if timer accuracy is required. ...

Page 9

... Keys are used to switch between setup menus, and the amount of time that you hold the keys down for determines which setup menu you move to. This section describes two typical examples. Note: In the following sections, “PV” is used to indicate a present value and “SV” to indicate a set value. 1. Using the H8GN as a Counter Typical Application Examples 1. Changing Set Values ...

Page 10

... Using the H8GN as a Timer Typical Application Examples 1. Changing Set Values Set value and selections in each display can be changed by pressing the and Keys. 2. Display No. 1 Display No. 2 Display Typical Application Examples Time range 0.0 to 999.9 s Timer mode DOWN (remaining time) Output mode ...

Page 11

... This level is for initializing settings, enabling SV-bank and totalizing counter use, setting display auto-return time, and move- to-protect- level time. • You can move to the initial setting level from this level. key once for less H8GN and Keys Key once for less than one sec- 11 ...

Page 12

... ON-duty ratio. value display Controlling the flowrate by opening and closing the electromagnetic valve by pulse control. ON duty (%) Control output Cycle time passed Refer to Input/Output Mode Settings on page 21 for information on ON/OFF-duty adjustable flicker mode operation. H8GN (1) Communications writing control ( ( ( ( (3) Cycle time Cycle time Close ...

Page 13

... Time Range (timr) The time range is displayed only when “Counter/Timer selec- tion” in the initial setting level has been set to timer. When the H8GN used as a timer, set the time range to be timed. 4. Timer Mode (timm) The timer mode is displayed only when “Counter/Timer selection” ...

Page 14

... The input signal edge will be displayed only when the “input mode” at the initial setting level has been set to increment or decrement. Switches the CP1 input edge when the H8GN is used as an incre- menting or decrementing counter. In the counter increment or decrement modes, CP2 will function as the gate input and CP1 counting will be prohibited while CP2 is ON ...

Page 15

... Prohibits the use of the Reset Key. Setting Meaning OFF PV and totalizing count values can be reset by the Reset Key and totalizing count values cannot be reset by the Reset Key. The default setting is OFF. H8GN Adjustment level Not protected No display, no level shift No display, no level shift No display, no level shift ...

Page 16

... Communications Data Length (len) The communications data length can be changed to either bits. 4. Stop Bits (sbit) The stop bits can be set to either Parity (prty) The parity can be set to none, even, or odd. Set value 9 euen H8GN 16 ...

Page 17

... When counter selected When counter selected When increment or decrement selected in counter input mode See note 3. H8GN Power ON Key less than 1s. Operation level See note 1. PV/SV Press the Key to PV reset the PV. Press the Key to reset the totalizing count value and Totalizing ...

Page 18

... Note: 1. Counter (increment or decrement 1,200 bps : 2,400 bps : 4,800 bps : 9,600 bps 2. Time range : None : Even : Odd 3. Displayed when level 0 is selected for initial setting/ communications protection in the protect level. H8GN Protect level : Level 0 Operation/ : Level 1 adjustment : Level 2 protection : Level 3 Initial : Level 0 settings/ ...

Page 19

... The following table explains the L and H symbols in the above graphics. Symbol H Short-circuited L Open CP1: Count input Count prohibit Count CP1: Count input Count prohibit Count Count Input H8GN Down (Decrement) mode (down) CP2: Count prohibit input Count prohibit n n-1 n-2 n-3 n-4 CP2: Count prohibit input Count prohibit n n-1 n-2 ...

Page 20

... Input mode Up Down t-a t t-a t-a t H8GN Up/Down B t-a t • Totalizing counter continues to count the present value, regardless of whether an reset input (by the reset key) has been made to reset the PV. • When totalizing count value is reset, the PV is reset at the same time. ...

Page 21

... Gate Reset Control output DOWN 0 E mode: Interval Power supply Start Gate Reset Control output DOWN 0 Z mode: ON/OFF-duty adjustable flicker Power supply Start Gate Reset Control output Cycle time ON duty setting (%) ON time 0 UP Cycle time ON duty setting (%) ON time DOWN 0 H8GN 21 ...

Page 22

... Note: Error codes are displayed only if PV/ being displayed. Error contents Memory error (RAM) Turn the power OFF and ON again. If normal operation is still not restored, it may be necessary to repair or replace the H8GN. If normal operation is Memory error (EEP) restored by turning the power supply OFF and ON possible that there CPU error is noise interference ...

Page 23

... Same as for PV in the above PV/SV column 99999999 0/1/2/3 H8GN Default Unit Set value value 0 1 off off ...

Page 24

... Setting range Default value 1 9 eUen H8GN Unit Set value Second Second Second Second Minute: Sec- ond Minute Hour: Minute Hour Hour Unit Set value Second Second Second Unit Set value kbps bit bit ...

Page 25

... ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Setting range Default value off off off off 3 H8GN Unit Set value Second Second 25 ...

Page 26

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords