■ Setting Specifications after Turning ON Power
Outline of Operation Procedure
Key Operation
In the following descriptions, all the parameters are introduced in the display sequence. Some parameters may not be displayed depending on the
protection settings and operating conditions.
Note: Of these levels, the initial setting level, communications setting level, and advanced function setting level can be used only when operation
Description of Each Level
Operation Level
• This level is displayed when you turn the power ON. You can move
• Normally, select this level during operation.
• During operation, the present value, set value, totalizing count
Adjustment Level
• To select this level, press the
• This level is for entering set value (SV 0 to 3) for operation. This
• You can move to the top parameter of the operation level, protect
Initial Setting Level
• To select this level, press the
• This level is for selecting the function, input mode, time range, timer
• You can move to the advanced function setting level or communica-
1 s. min.
to the protect level, initial setting level, and adjustment level from
this level.
value, and setting number of SV-bank can be monitored using the
ond.
level contains parameters for communications writing enable/dis-
able, set value of SV-bank, and cycle time (timer Z mode).
level, or initial setting level from here.
the operation level or adjustment level.
mode, output mode, output time, counting speed, input signal
width, decimal point position, prescale value, and rising/falling edge
for input signal.
tions setting level from this initial setting level. To return to the oper-
ation level, press the
the communications setting level, press the
than one second.
1 s. min.
Initial setting level
Advanced function
setting level
Key
has stopped. Control output is stopped when these three levels are selected. When switched back to the operation level from one of these
levels, operation will start.
Operation level
Key.
Key
Power ON
3 s min.
Password input set value "−169"
Key
less than 1 s.
less than 1 s.
Key for at least one second. To move to
Key
Key
Key for at least three seconds in
Key once for less than one sec-
Operation stops
Adjustment level
Communications
setting level
key once for less
Keys 1 s. min.
3 s. min. (default value)
+
+
Protect Level
• To select this level, simultaneously press the
Communications Setting Level
• To select this level, press the
Advanced Function Setting Level
• To select this level, you must change the initial settings/communica-
• This level is for initializing settings, enabling SV-bank and totalizing
• You can move to the initial setting level from this level.
Key
for at least three seconds (default value). This level is to prevent
unwanted or accidental modification of parameters. Protected lev-
els will not be displayed, and so the parameters in that level cannot
be modified.
ond in the initial setting level. When the communications function is
used, set the communications conditions in this level. Communicat-
ing with a personal computer (host computer) allows set values to
be read and written.
tions protection setting in the protect level to “0” and then enter the
password (“−169”) in the initial setting level.
counter use, setting display auto-return time, and move- to-protect-
level time.
Protect level
Operation in progress
Operation stopped
Not displayed depending on model and settings.
Not displayed depending on model and settings.
Level change
Key once for less than one sec-
and
H8GN
Keys
11