■ Troubleshooting
When an error occurs, the error code is displayed on the main display. Take countermeasures according to the code.
Note: Error codes are displayed only if PV/SV or PV is being displayed.
e111
e111
e1
- - - -
Flashes
No. 1 display
No display
sum
No display
Set value displayed or
no display
No. 2 display
Memory error (RAM)
Memory error (EEP)
CPU error
Present value under-
flow
Error contents
Turn the power OFF and ON again. If normal operation is still not restored,
it may be necessary to repair or replace the H8GN. If normal operation is
restored by turning the power supply OFF and ON, it is possible that there
is noise interference. Check that there is nothing in the vicinity that may be
the source of noise.
This is not an actual error. This display indicates that the present value has
dropped to a value less than −999. Reset using reset input or pressing the
Up Key when “– – – –” is displayed.
Countermeasure