TL71 Fluke Electronics, TL71 Datasheet - Page 44

TEST LEAD SET 10A

TL71

Manufacturer Part Number
TL71
Description
TEST LEAD SET 10A
Manufacturer
Fluke Electronics
Datasheet

Specifications of TL71

Current Rating
10A
Termination
Banana Plug, Sheathed, Right Angle
Color
Black and Red - Plugs and Wire; Gray - Probes
Ratings
CAT IV, 600V; CAT III, 1000V
Wire Insulation Material
Silicone
Includes
Pin Tip
For Use With
614-1085 - MULTIMETER INDUSTRIAL 1000V CATFLUKE-116 - MULTIMETER HVAC TRUE RMS614-1061 - DMM TRUE RMS 50000CNT W/BCKLGHT614-1020 - DMM TRE RMS W/BCKLGT 6000CNT DIS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Max
-
Impedance
-
Cable Length
-
Other names
1274382
614-1054

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TL7100E
Manufacturer:
SMD
Quantity:
30
Part Number:
TL71025
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL7102BC
Manufacturer:
MOLEX
Quantity:
26 000
Part Number:
TL710CN
Manufacturer:
TI
Quantity:
5 510
Part Number:
TL710CN
Manufacturer:
ALTERA
Quantity:
5 510
Company:
Part Number:
TL710CN
Quantity:
200
Part Number:
TL710CP
Manufacturer:
TI
Quantity:
1 440
Part Number:
TL710CP
Manufacturer:
TI
Quantity:
1 000
Part Number:
TL710CP
Manufacturer:
TI
Quantity:
1 000
Part Number:
TL710CP
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL712C
Quantity:
2 932
Part Number:
TL712CD
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL712CDR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL712CP
Manufacturer:
TI/德州仪器
Quantity:
20 000

For more information and detailed specifications, go to www.fluke.com/processmeters
Process Calibration Tools
Range
-20.99 mA to +20.99 mA
-21.0 mA to -99.9 mA
+21.0 mA to +99.9 mA
Range
Accuracy
Stability
Well-to-well
uniformity
Stabilization
Well depth
Removable inserts
Power
Size (H x W x D)
Weight
NIST-traceable
calibration
Save time and money troubleshooting
9100S
35 °C to 375 °C (95 °F to 707 °F)
± 0.5 °C
± 0.1 °C at 100 °C ± 0.3 °C at 375 °C
± 0.2 °C with sensors of similar size at equal depths within wells
5 minutes
102 mm (4 in); 1.6 mm (1/16 in) hole is 89 mm (3.5
in) deep
N/A
115 V ac (± 10 %), 1.5 A or 230 V ac (± 10 %, 0.8 A,
specify, 50/60 Hz, 175 W
57 mm x 125 mm x 150 mm (2.25 in x 4.9 in x 5.9 in)
1 kg (2 lb, 3 oz)
Data at 50 °C, 150 °C, 200 °C, 250 °C, 300 °C and
350 °C
9102S and 9100S Handheld Drywell
Process Clamp Meter
Resolution
0.01 mA
0.1 mA
Fluke Corporation, Hart Scientific Division
The innovative new Fluke 771 mA Process Clamp Meter is
designed to measure, test, and troubleshoot 4-20 mA control sig-
nals without breaking the mA loop. Make mA measurements in
active control systems without disrupting process control.
Features:
Key uses:
Best in class 0.2 % accuracy
Resolution and sensitivity to 0.01 mA
Hold function captures and displays changing measurements
Dual display with both mA measurement and 0 % to 100 % of
4 mA to 20 mA span
Measurement spotlight illumination hard to see wires in dark
enclosures
Detachable clamp with extension cable for measurements in
tight locations
Includes carrying case that can be used as a belt mounted
holster
Measure mA signals for PLC and control system analog I/O
Measure 4 mA to 20 mA output signals from transmitters
Measure 10 mA to 50 mA signals in older control systems
using the 99.9 mA range
Accuracy
0.2 % or reading
+ 5 counts
1 % reading
+ 5 counts
Fluke 771 Milliamp
The smallest, lightest and most
portable dry-wells in the world
Temperature Calibrators
9100 model weighs only 2 pounds, 3 ounces
(1 kilogram)
Temperature ranges from -10 °C to 375 °C
Stability during calibrations to ± 0.05 °C
Fast and easy calibrations of RTDs and
thermocouples
Includes RS-232 interface, instrument
control software
Direct interface to the Fluke 744
process control loops
Features
Zero, Hold, backlight,
measurement spotlight
Zero, Hold, backlight,
measurement spotlight
910S
-10 °C to 122 °C (14 °F to 252 °F) at 23 °C ambient
± 0.25 °C
± 0.05 °C at 0 °C
7 minutes
102 mm (4 in)
1/4 in, 3/16 in (Standard) 1/16 in, 1/8 in, 3/8 in
(optional)
94 V ac to 234 V ac (± 10 %), 50/60 Hz, 60 W; or
12 V dc
99 mm x 140 mm x 175 mm (3.9 in x 5.5 in x 6.9 in)
1.8 kg (4 lb)
Data at -10 °C, 24 °C, 50 °C, 55 °C, 100 °C and 122 °C
N10140
Notes
Use for measuring and troubleshooting
4 mA to 20 mA signals
Use for measuring and troubleshooting
10 mA to 50 mA signals
Detachable clamp used to measure 4 mA
to 20 mA signals on transmitters without
breaking the loop.
Fluke 771
included accessories
Carrying case, and instruction
manual.
Ordering information
Fluke-771
9102S and 9100S
ordering information
9100S-A-156 Dry-Well, Block A
9100S-A-256 Dry-Well, Block A
9100S-B-156 Dry-Well, Block B
9100S-B-256 Dry-Well, Block B
9100S-D-156 Dry-Well, Block D
9100S-D-256 Dry-Well, Block D
9300
9102S-156
9102S-256
9320-156
9320-256
9102S and 9009
inserts
3102-1
3102-2
3102-3
3102-4
3102-6
3102-7
3102-8
9308
(1)
(2)
(3)
156 Blocks are 115 V 50/60 Hz
256 Blocks are 220 V 50/60 Hz
Specify two 3102 inserts
Milliamp Process
Clamp Meter
Rugged Carrying
Case, 9100
Dry-Well, -10 to 122
(2 Wells)
Dry-Well, -10 to 122
(2 Wells)
Battery Pack, 9102
Battery Pack, 9102
Insert, AL 1/16 in
(1.6 mm)
Insert, AL 1/8 in
(3.2 mm)
Insert, AL 3/16 in
(4.8 mm)
Insert, AL 1/4 in
(6.4 mm) (Standard)
Insert, AL 3/8 in
(9.5 mm) (Standard)
Insert, AL 7/16 in
(11.1 mm) (Standard)
Insert, AL 5/32 in
(4 mm) (Standard)
Hard Carrying Case,
9102/9132
(1) (3)
(2) (3)
(1)
(2)
(1)
(2)
(1)
(2)
(1)
(2)