TL71 Fluke Electronics, TL71 Datasheet - Page 47

TEST LEAD SET 10A

TL71

Manufacturer Part Number
TL71
Description
TEST LEAD SET 10A
Manufacturer
Fluke Electronics
Datasheet

Specifications of TL71

Current Rating
10A
Termination
Banana Plug, Sheathed, Right Angle
Color
Black and Red - Plugs and Wire; Gray - Probes
Ratings
CAT IV, 600V; CAT III, 1000V
Wire Insulation Material
Silicone
Includes
Pin Tip
For Use With
614-1085 - MULTIMETER INDUSTRIAL 1000V CATFLUKE-116 - MULTIMETER HVAC TRUE RMS614-1061 - DMM TRUE RMS 50000CNT W/BCKLGHT614-1020 - DMM TRE RMS W/BCKLGT 6000CNT DIS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Max
-
Impedance
-
Cable Length
-
Other names
1274382
614-1054

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TL7100E
Manufacturer:
SMD
Quantity:
30
Part Number:
TL71025
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL7102BC
Manufacturer:
MOLEX
Quantity:
26 000
Part Number:
TL710CN
Manufacturer:
TI
Quantity:
5 510
Part Number:
TL710CN
Manufacturer:
ALTERA
Quantity:
5 510
Company:
Part Number:
TL710CN
Quantity:
200
Part Number:
TL710CP
Manufacturer:
TI
Quantity:
1 440
Part Number:
TL710CP
Manufacturer:
TI
Quantity:
1 000
Part Number:
TL710CP
Manufacturer:
TI
Quantity:
1 000
Part Number:
TL710CP
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL712C
Quantity:
2 932
Part Number:
TL712CD
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL712CDR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL712CP
Manufacturer:
TI/德州仪器
Quantity:
20 000
Specifications – Ti40 and Ti50 Series
Battery life: 3 hours continuous operation (2 hours on FT models)
Water and dust resistant: IP54
Size (HxWxD): 162 mm x 262 mm x 101 mm (6.378 in x 10.315 in x 3.9764 in)
Weight: 1.85 kg (4.07 lb)
Two-year warranty
Recommended accessories – Ti0 and Ti50 Series Imagers
Thermal imaging performance
Field of view (FOV)*
Spatial resolution (IFOV)*
Min focus distance*
Thermal sensitivity (NETD) at 30 °C
Detector data acquisition/image frequency
Focus
IR digital zoom
Detector size
Detector type
Spectral band
Visual Imaging performance (Fusion models only)
On-camera operating modes
Visible light camera
Visible light digital zoom
Visible color alarm above and below
Temperature measurement
Calibrated temperature range
1200 °C High temperature option
Accuracy
Measurement modes
Emissivity correction
Image presentation
Digital display
Video output
Palettes
Optional lenses
54 mm Telephoto lens
Field of view (FOV)
Spatial resolution (IFOV)
Min focus distance
10.5 mm wide angle lens
Field of view (FOV)
Spatial resolution (IFOV)
Min focus distance
Image and data storage
Storage medium
File formats supported
Interfaces and software
Interface
Included software
Laser (IR-Fusion models only)
Classification
Laser targeting
Controls and adjustments
Set-up controls
Image controls
On-screen indicators
Anti-glare Hood
Picture-in-Picture
Full thermal, full visual light or merged thermal-visual images
Centerpoint, center box (area min/max, average)
Moveable spots/boxes
Isotherms, automatic hot and cold point detection
FlexCam
10
Ti40 and Ti50 Series IR
professionals demanding the best
Car Charger
105
®
Thermal Imagers
The thermal imagers for
Battery Charger
SmartView; Full analysis and reporting software
Smartview
Ti-SBC
Grayscale, grayscale inverted, blue red, high contrast, hot
-20 °C to
≤0.09 °C
Compact flash card (512Mb) stores over 1000 IR images
Data formats: comma separated (csv), tab separated (txt)
Battery status, emissivity, background temperature and
350 °C
Fluke
Ti0
only
Focal Plane Array, Vanadium Oxide (VOx) Uncooled
Date/time, °C/°F, language, scale, LCD intensity
1280 x 1024 pixels, full color (1.3 megapixels)
RS170 EIA/NTSC or CCIR/PAL composite video
Laser dot visible on blended and visual image
30 Hz/30 Hz
Level, span, auto adjust (continuous/manual)
160 x 120
2.60 mrad
SmartFocus; single finger continuous focus
0.94 mrad
4.9 mrad
metal, ironbow, amber, amber inverted
5” large high-resolution backlight LCD
± 2 °C or 2 % (whichever is greater)
Compact flash card reader included
14 bit measurement data included.
High precision Germanium lens
High precision Germanium lens
Images: bmp, gif, jpg, png, tiff;
Fluke Ti5
23° horizontal x 17° vertical
0.1 to 1.0 (0.01 increments)
42° horizontal x 32° vertical
-20 °C to
≤0.08 °C
9° horizontal x 6° vertical
600 °C
2x
2x
Microbolometer
8 µm to 14 µm
real time clock
0.15 m
Class II
0.6 m
0.3 m
Rechargeable Battery Pack
-20 °C to
≤0.07 °C
350 °C
Fluke
Ti50
2x
2x
60 Hz/60 Hz
Ti-SBP
320 x 240
1.30 mrad
0.47 mrad
2.45 mrad
Fluke Ti55
2x, 4x. 8x
-20 °C to
≤0.05 °C
600 °C
2x, 4x
Fluke SmartView
analysis and reporting
software for Fluke IR
cameras.
Included with each Fluke IR
thermal imager, Fluke SmartView
software is a modular suite of
tools that annotates, views, edits
and analyzes IR images. It also
generates fully customizable and
professional-looking reports in
a few easy steps. The IR-Fusion
technology is full supported.
The software is easy to use for
the technician, yet delivers the
performance specialized ther-
mographers require for advanced
analysis.
Included accessories
AC adapter (for Ti45 and Ti55 only),
video cable, 512 MB compact flash
card, compact flash card reader and
USB cable, PCMCIA compact flash
card adapter, SmartView report-
ing and analysis software on CD, 2
rechargeable battery packs, battery
charger, neck strap, heavy duty car-
rying case and user manual on CD.
Ordering information
Fluke-Ti40-20
Fluke-Ti40FT-20 IR FlexCam
Fluke-Ti45-20
Fluke-Ti45FT-20 IR FlexCam
Fluke-Ti50-20
Fluke-Ti50FT-20 IR FlexCam
Fluke-Ti55-20
Fluke-Ti55FT-20 IR FlexCam
*For ordering information of optional
lenses check the Fluke web.
Thermal Imaging
IR FlexCam
Thermal Imager
Thermal Imager
with IR-Fusion
IR FlexCam
Thermal Imager
Thermal Imager
with IR-Fusion
IR FlexCam
Thermal Imager
Thermal Imager
with IR-Fusion
IR FlexCam
Thermal Imager
Thermal Imager
with IR-Fusion
IR
7