TL71 Fluke Electronics, TL71 Datasheet - Page 67

TEST LEAD SET 10A

TL71

Manufacturer Part Number
TL71
Description
TEST LEAD SET 10A
Manufacturer
Fluke Electronics
Datasheet

Specifications of TL71

Current Rating
10A
Termination
Banana Plug, Sheathed, Right Angle
Color
Black and Red - Plugs and Wire; Gray - Probes
Ratings
CAT IV, 600V; CAT III, 1000V
Wire Insulation Material
Silicone
Includes
Pin Tip
For Use With
614-1085 - MULTIMETER INDUSTRIAL 1000V CATFLUKE-116 - MULTIMETER HVAC TRUE RMS614-1061 - DMM TRUE RMS 50000CNT W/BCKLGHT614-1020 - DMM TRE RMS W/BCKLGT 6000CNT DIS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Max
-
Impedance
-
Cable Length
-
Other names
1274382
614-1054

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TL7100E
Manufacturer:
SMD
Quantity:
30
Part Number:
TL71025
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL7102BC
Manufacturer:
MOLEX
Quantity:
26 000
Part Number:
TL710CN
Manufacturer:
TI
Quantity:
5 510
Part Number:
TL710CN
Manufacturer:
ALTERA
Quantity:
5 510
Company:
Part Number:
TL710CN
Quantity:
200
Part Number:
TL710CP
Manufacturer:
TI
Quantity:
1 440
Part Number:
TL710CP
Manufacturer:
TI
Quantity:
1 000
Part Number:
TL710CP
Manufacturer:
TI
Quantity:
1 000
Part Number:
TL710CP
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL712C
Quantity:
2 932
Part Number:
TL712CD
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL712CDR
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
TL712CP
Manufacturer:
TI/德州仪器
Quantity:
20 000
* Requires PM9081/001 Adapter
** Requires PM9082/001 Adapter
For more information and detailed specifications, go to www.fluke.com/accessories
DC range
AC range
Accuracy
Bandwidth (-3 dB)
Zero error
adjustment
Maximum
conductor
diameter
Maximum
conductor size
Output levels
Output cable
Battery life
Warranty
Safety
AC/DC current clamp specifications
Power quality ac combo packs
for 4-phase current measurements
i430flex 4-pack
i5sPQ3
to 1 kHz: ± 3 % +
11.8 mm (0.46 in)
CAT II 600 V; CAT
0.1 A to 10 A; dc
100 A add 15 %;
20 kHz add 12 %
0.1 A to 100 A
1.6 meter with
10 mV/A, 100
0.1 A to 70 A
50 mA; up to
For use with DMMs, ScopeMeters
termination
80i-110s
One-year
40 hours
100 kHZ
III 300 V
1 AWG
up to
mV/A
BNC
Yes
Fluke current clamps
and Power Quality Analyzers
3.5 % + 0.5 A for
shrouded banana
30 mm (1.18 in)
750 MCM or 2-
1.2 meter with
(45 to 400 Hz)
CAT III 600 V
1 A to 400 A
1 to 400 A
500 MCM
60 hours
One-year
dc or ac
1 mV/A
3 kHz
i10
plugs
Yes
shrouded banana
30 mm (1.18 in)
2 % + 0.5 A for
750 MCM or 2-
1.2 meter with
(45 to 400 Hz)
CAT III 600 V
1 A to 600 A
1 to 1000 A
500 MCM
60 hours
One-year
dc or ac
1 mV/A
i1010
10 kHz
plugs
Yes
4 mA to 20 A rms
19 mm (0.75 in)
1.5 meter with
± 1 % ± 2 mA
shrouded dual
4 mA to 20 A
CAT III 300 V
dc to 20 kHz
banana plue
100 mV/A
250 MCM
30 hours
One-year
(-0.5 dB)
i0
Yes
4 mA to 20 A rms
2 meter with BNC
19 mm (0.75 in)
± 1 % ± 2 mA
dc to 100 kHz
4 mA to 20 A
CAT III 300 V
termination
100 mV/A
250 MCM
One-year
(-0.5 dB)
30 hours
i0s
Yes
80i-110s
AC/DC models
i0s and i0 Hall Effect
AC/DC Current Clamps
i30s
i30
i410
i1010
Use with multimeters or
recorders for non-intrusive
current measurements
Accessories