C8051T600-GS Silicon Laboratories Inc, C8051T600-GS Datasheet - Page 100

IC 8051 MCU 8K OTP 14SOIC

C8051T600-GS

Manufacturer Part Number
C8051T600-GS
Description
IC 8051 MCU 8K OTP 14SOIC
Manufacturer
Silicon Laboratories Inc
Series
C8051T60xr
Datasheets

Specifications of C8051T600-GS

Program Memory Type
OTP
Program Memory Size
8KB (8K x 8)
Package / Case
14-SOIC (3.9mm Width), 14-SOL
Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
SMBus (2-Wire/I²C), UART/USART
Peripherals
POR, PWM, Temp Sensor, WDT
Number Of I /o
8
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
C8051T6x
Core
8051
Data Bus Width
8 bit
Data Ram Size
256 B
Interface Type
I2C/SMBus/UART
Maximum Clock Frequency
25 MHz
Number Of Programmable I/os
8
Number Of Timers
3
Operating Supply Voltage
1.8 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051T600DK
Minimum Operating Temperature
- 40 C
On-chip Adc
8-ch x 10-bit
Package
14SOIC
Device Core
8051
Family Name
C8051T60x
Maximum Speed
25 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1665 - BOARD DAUGHTER FOR C8051T600E336-1404 - KIT DEV FOR C8051T60X MCU'S
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1403-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051T600-GS
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
C8051T600/1/2/3/4/5/6
21. Oscillators and Clock Selection
C8051T600/1/2/3/4/5/6 devices include a programmable internal high-frequency oscillator and an external
oscillator drive circuit. The internal high-frequency oscillator can be enabled/disabled and calibrated using
the OSCICN and OSCICL registers, as shown in Figure 21.1. The system clock can be sourced by the
external oscillator circuit or the internal oscillator (default). The internal oscillator offers a selectable post-
scaling feature, which is initially set to divide the clock by 8.
OSCICL
OSCICN
RC Mode
VDD
EXTCLK
EN
Programmable
n
Internal Clock
Generator
SYSCLK
C Mode
EXTCLK
Input
EXTCLK
OSC
Circuit
CMOS Mode
EXTCLK
OSCXCN
Figure 21.1. Oscillator Options
21.1. System Clock Selection
The CLKSL bit in register OSCICN selects which oscillator source is used as the system clock. CLKSL
must be set to 1 for the system clock to run from the external oscillator; however the external oscillator may
still clock certain peripherals (timers, PCA) when the internal oscillator is selected as the system clock. The
system clock may be switched on-the-fly between the internal oscillator and external oscillator, as long as
the selected clock source is enabled and running.
The internal high-frequency oscillator requires little start-up time and may be selected as the system clock
immediately following the register write, which enables the oscillator. The external RC and C modes also
typically require no startup time.