C8051T600-GS Silicon Laboratories Inc, C8051T600-GS Datasheet - Page 125

IC 8051 MCU 8K OTP 14SOIC

C8051T600-GS

Manufacturer Part Number
C8051T600-GS
Description
IC 8051 MCU 8K OTP 14SOIC
Manufacturer
Silicon Laboratories Inc
Series
C8051T60xr
Datasheets

Specifications of C8051T600-GS

Program Memory Type
OTP
Program Memory Size
8KB (8K x 8)
Package / Case
14-SOIC (3.9mm Width), 14-SOL
Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
SMBus (2-Wire/I²C), UART/USART
Peripherals
POR, PWM, Temp Sensor, WDT
Number Of I /o
8
Ram Size
256 x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Processor Series
C8051T6x
Core
8051
Data Bus Width
8 bit
Data Ram Size
256 B
Interface Type
I2C/SMBus/UART
Maximum Clock Frequency
25 MHz
Number Of Programmable I/os
8
Number Of Timers
3
Operating Supply Voltage
1.8 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
C8051T600DK
Minimum Operating Temperature
- 40 C
On-chip Adc
8-ch x 10-bit
Package
14SOIC
Device Core
8051
Family Name
C8051T60x
Maximum Speed
25 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
336-1665 - BOARD DAUGHTER FOR C8051T600E336-1404 - KIT DEV FOR C8051T60X MCU'S
Eeprom Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1403-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051T600-GS
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
after SCL transitions from high-to-low. EXTHOLD should be set so that the minimum setup and hold times
meet the SMBus Specification requirements of 250 ns and 300 ns, respectively. Table 23.2 shows the min-
imum setup and hold times for the two EXTHOLD settings. Setup and hold time extensions are typically
necessary when SYSCLK is above 10 MHz.
With the SMBTOE bit set, Timer 3 should be configured to overflow after 25 ms in order to detect SCL low
timeouts (see Section “23.3.4. SCL Low Timeout” on page 122). The SMBus interface will force Timer 3 to
reload while SCL is high, and allow Timer 3 to count when SCL is low. The Timer 3 interrupt service routine
should be used to reset SMBus communication by disabling and re-enabling the SMBus.
SMBus Free Timeout detection can be enabled by setting the SMBFTE bit. When this bit is set, the bus will
be considered free if SDA and SCL remain high for more than 10 SMBus clock source periods (see
Figure 23.4).
Note: Setup Time for ACK bit transmissions and the MSB of all data transfers. When using
EXTHOLD
software acknowledgement, the s/w delay occurs between the time SMB0DAT or
ACK is written and when SI is cleared. Note that if SI is cleared in the same write
that defines the outgoing ACK value, s/w delay is zero.
0
1
Table 23.2. Minimum SDA Setup and Hold Times
Minimum SDA Setup Time
1 system clock + s/w delay
T
low
11 system clocks
– 4 system clocks
or
Rev. 1.2
*
C8051T600/1/2/3/4/5/6
Minimum SDA Hold Time
12 system clocks
3 system clocks
125