Description
IC ENCORE MCU FLASH 4K 28SOIC
Manufacturer
Zilog
Series
Encore!® XP®r
Datasheet

Specifications of Z8F0422SJ020EG

Core Processor
Z8
Core Size
8-Bit
Speed
20MHz
Connectivity
I²C, IrDA, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
19
Program Memory Size
4KB (4K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 5x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 105°C
Package / Case
28-SOIC (7.5mm Width)
Processor Series
Z8F042xx
Core
eZ8
Data Bus Width
8 bit
Data Ram Size
1 KB
Interface Type
I2C, SPI, UART
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
19
Number Of Timers
2
Operating Supply Voltage
2.7 V to 3.6 V
Maximum Operating Temperature
+ 105 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 5 Channel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
269-4142
Z8F0422SJ020EG
PS022517-0508
COMPARE Mode
When the timer is disabled, the Timer Output signal is set to the value of this bit. When the
timer is enabled, the Timer Output signal is complemented upon timer Reload.
GATED Mode
0 = Timer counts when the Timer Input signal is High (1) and interrupts are
1 = Timer counts when the Timer Input signal is Low (0) and interrupts are
CAPTURE/COMPARE Mode
0 = Counting is started on the first rising edge of the Timer Input signal. The
1 = Counting is started on the first falling edge of the Timer Input signal. The
PRES—Prescale value
The timer input clock is divided by 2
reset each time the Timer is disabled. This insures proper clock division each time the
Timer is restarted.
000 = Divide by 1
001 = Divide by 2
010 = Divide by 4
011 = Divide by 8
100 = Divide by 16
101 = Divide by 32
110 = Divide by 64
111 = Divide by 128
TMODE—Timer Mode
000 = ONE-SHOT mode
001 = CONTINUOUS mode
010 = COUNTER mode
011 = PWM mode
100 = CAPTURE mode
101 = COMPARE mode
110 = GATED mode
111 = CAPTURE/COMPARE mode
generated on the falling edge of the Timer Input.
current count is captured on subsequent rising edges of the Timer Input signal.
generated on the rising edge of the Timer Input.
current count is captured on subsequent falling edges of the Timer Input signal.
PRES
, where PRES is set from 0 to 7. The prescaler is
Z8 Encore! XP
Product Specification
®
F0822 Series
Timers
82