ST62T01CM6 STMicroelectronics, ST62T01CM6 Datasheet - Page 12

IC MCU 8BIT OTP 2K 16-SOIC

ST62T01CM6

Manufacturer Part Number
ST62T01CM6
Description
IC MCU 8BIT OTP 2K 16-SOIC
Manufacturer
STMicroelectronics
Series
ST6r
Datasheet

Specifications of ST62T01CM6

Core Processor
ST6
Core Size
8-Bit
Speed
8MHz
Peripherals
LVD, POR, WDT
Number Of I /o
9
Program Memory Size
2KB (2K x 8)
Program Memory Type
OTP
Ram Size
64 x 8
Voltage - Supply (vcc/vdd)
3 V ~ 6 V
Data Converters
A/D 4x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
16-SOIC (0.300", 7.5mm Width)
Processor Series
ST62T0x
Core
ST6
Data Bus Width
8 bit
Data Ram Size
64 B
Maximum Clock Frequency
8 MHz
Number Of Programmable I/os
9
Number Of Timers
2
Operating Supply Voltage
3 V to 6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Development Tools By Supplier
ST622XC-KIT/110, ST62GP-EMU2, ST62E2XC-EPB/110, ST62E6XC-EPB/US, STREALIZER-II
Minimum Operating Temperature
- 40 C
On-chip Adc
8 bit
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Connectivity
-
Lead Free Status / Rohs Status
In Transition
Other names
497-2095-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ST62T01CM6
Quantity:
1 035
Part Number:
ST62T01CM6
Manufacturer:
ST
Quantity:
1 000
Part Number:
ST62T01CM6/BC
Manufacturer:
ST
0
ST6200C ST6201C ST6203C
MEMORY MAP (Cont’d)
3.1.6 Data ROM Window
The Data read-only memory window is located
from address 0040h to address 007Fh in Data
space. It allows direct reading of 64 consecutive
bytes located anywhere in program memory, be-
tween address 0000h and 0FFFh.
There are 64 blocks of 64 bytes in a 4K device:
– Block 0 is related to the address range 0000h to
– Block 1 is related to the address range 0040h to
and so on...
All the program memory can therefore be used to
store either instructions or read-only data. The
Data ROM window can be moved in steps of 64
bytes along the program memory by writing the
appropriate code in the Data ROM Window Regis-
ter (DRWR).
Figure 5. Data ROM Window
12/100
1
0FFFh
0000h
003Fh.
007Fh.
PROGRAM
SPACE
64-BYTE
ROM
0FFh
000h
040h
07Fh
DATA SPACE
DATA ROM
WINDOW
Doc ID 4563 Rev 5
3.1.6.1 Data ROM Window Register (DRWR)
The DRWR can be addressed like any RAM loca-
tion in the Data Space.
This register is used to select the 64-byte block of
program memory to be read in the Data ROM win-
dow (from address 40h to address 7Fh in Data
space). The DRWR register is not cleared on re-
set, therefore it must be written to before access-
ing the Data read-only memory window area for
the first time.
Address: 0C9h — Write Only
Reset Value = xxh (undefined)
Bits 7:6 = Reserved, must be cleared.
Bit 5:0 = DRWR[5:0] Data read-only memory Win-
dow Register Bits. These are the Data read-only
memory Window bits that correspond to the upper
bits of the data read-only memory space.
Caution: This register is undefined on reset, it is
write-only, therefore do not read it nor access it us-
ing Read-Modify-Write instructions (SET, RES,
INC and DEC).
7
-
-
DRWR5 DRWR4 DRWR3 DRWR2 DRWR1 DRWR0
0