MC68HC908GP32CP Freescale Semiconductor, MC68HC908GP32CP Datasheet - Page 329

IC MCU 8MHZ 32K FLASH 40-DIP

MC68HC908GP32CP

Manufacturer Part Number
MC68HC908GP32CP
Description
IC MCU 8MHZ 32K FLASH 40-DIP
Manufacturer
Freescale Semiconductor
Series
HC08r
Datasheet

Specifications of MC68HC908GP32CP

Core Processor
HC08
Core Size
8-Bit
Speed
8MHz
Connectivity
SCI, SPI
Peripherals
LVD, POR, PWM
Number Of I /o
33
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
40-DIP (0.600", 15.24mm)
For Use With
M68EVB908GP32 - BOARD EVALUATION FOR HC908GP32
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68HC908GP32CP
Manufacturer:
ROCKWELL
Quantity:
201
Part Number:
MC68HC908GP32CP
Manufacturer:
MOTOROLA/摩托罗拉
Quantity:
20 000
20.13.5 CGND (Clock Ground)
MC68HC908GP32
MOTOROLA
MC68HC08GP32
When an SPI is configured as a master, the SS input can be used in
conjunction with the MODF flag to prevent multiple masters from driving
MOSI and SPSCK.
SS pin to set the MODF flag, the MODFEN bit in the SPSCK register
must be set. If the MODFEN bit is low for an SPI master, the SS pin can
be used as a general-purpose I/O under the control of the data direction
register of the shared I/O port. With MODFEN high, it is an input-only pin
to the SPI regardless of the state of the data direction register of the
shared I/O port.
The CPU can always read the state of the SS pin by configuring the
appropriate pin as an input and reading the port data register.
Table
CGND is the ground return for the serial clock pin, SPSCK, and the
ground for the port output buffers. It is internally connected to V
shown in
Note 1. X = Don’t care
SPE
0
1
1
1
20-3.)
Serial Peripheral Interface Module (SPI)
SPMSTR
Rev. 6
Table
X
0
1
1
(1)
20-1.
MODFEN
(See 20.8.2 Mode Fault
Table 20-3. SPI Configuration
X
X
0
1
Master without MODF
SPI Configuration
Master with MODF
Not enabled
Slave
Serial Peripheral Interface Module (SPI)
Error.) For the state of the
General-purpose I/O;
General-purpose I/O;
State of SS Logic
SS ignored by SPI
SS ignored by SPI
Input-only to SPI
Input-only to SPI
Technical Data
I/O Signals
(See
SS
as
327