WLCL-TS Omron, WLCL-TS Datasheet - Page 40

SW LIMIT ADJ ROD LVR SPDT 10A

WLCL-TS

Manufacturer Part Number
WLCL-TS
Description
SW LIMIT ADJ ROD LVR SPDT 10A
Manufacturer
Omron
Series
WLr
Type
General Purpose Limit Switchr
Datasheet

Specifications of WLCL-TS

Circuit
SPDT-DM/DB
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Adjustable Rod
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
142gf
Contact Form
1 NC / 4 NO
Contact Rating
10 Amps at 125 Volts
Actuator
Lever, Rod
Actuator Style
Flexible Rod
Operating Force Max
1.39N
Contact Voltage Ac Max
500V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
800mA
Switch Terminals
Screw
Current Rating (max)
10A
Operating Temp Range
-10C to 80C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
WLCLTS
Z2752
Built-in Switch
Do not remove or replace the built-in switch. If the position of the built-
in switch moves, it can cause reduced performance, and if the
insulation sheet moves (separator), the insulation may become
ineffective.
Tightening Torque
Installing the Switch
To install the Switch, make a mounting panel, as shown in the
following diagram, and tighten screws using the correct torque.
Mounting
Mounting
1.
6.
5.
• If screws are too loose they can lead to an early malfunction of the
• In particular, when changing the direction of the Head, make sure
Front Mountig/
Rear Mountig
Side Mountig
Switch, so ensure that all screws are tightened using the correct
torque.
that all screws are tightened again to the correct torque. Do not
allow foreign objects to fall into the Switch.
In case of side mounting for
overtravel,90
Front Mountig :
Rear Mountig :
58.7
Two, 5.2
3.
4.
2.
WL
±0.15
°
No.
WL@-@@2N
1.
2.
3.
4.
5.
30.2
23
+0.2
0
Four, 5.2
or M5 tapped holes
Four, 6.2
±0.15
dia. holes
±0.15
Head mounting
screw
Cover mounting
screw
Allen-head bolt
(for securing the
lever)
Terminal screw
Connector
64
±0.15
+0.2
+0.2
0
0
Type
dia. holes
dia. holes
0.78 to 0.88 N·m
1.18 to 1.37 N·m
4.90 to 5.88 N·m
0.59 to 0.78 N·m
1.77 to 2.16 N·m
Appropriate
Mounting
locations
Mounting
locations
tightening
torque
Connectors
Either the easy-to-use Allen-head nut or the SC Connector can be
used as connectors. To ensure high-sealing properties, use the SC
Connector. Refer to Limit Switch Connectors for details on SC
Connectors.
Wiring
Rotating Lever Set Position (General-purpose or Spatter-
prevention Switches Only)
All rotating lever models, except the fork lever lock models, have a set
position marker plate. (See page 23.) After operation, set the indicator
needle on the marker plate so that is in the convex section of the
bearing.
Operation Set Position (Long-life Switches Only)
For all Long-life Switching, there is a set position marker slit on the
rubber cap of the head. After operation, set the slit on the rubber cap
so that the fluorescent color on the shaft section can be seen.
Terminal Plate
By using a short circuit plate, as shown in the following diagram, the
Switch can be fabricated into a single-polarity double-break switch.
When ordering, specify WL Terminal Plate (product code: WL-
9662F).
Indicator
Indicator-equipped switch has contacts and indicator in parallel.
When contacts are open, leakage current flows through the indicator
circuit and may cause load's malfunction.
Please check the load's OFF current before use the indicator-
equipped switch.
• Use 1.25-mm
• The ground terminal is only installed on models with ground
terminals for wiring.
terminals.
Crimp Terminal External
Dimensions
D dia.
dz dia. : 4.3
D dia. : 4.5
B
L
F
l
: 8.5
: 21.0
: 7.8
: 9.0 (mm)
l
2.5
9
2
±0.2
+0.2
lead wires and M4-insulation covered crimp
0
L
2.1R
F
dz dia.
4.2
COM
9
+0.1
0
7
B
16
3.5
±0.15
t = 0.6 Brass plate
Wiring Method
Switch Box Section
23
Ground terminal
±0.4
NO terminal
NC terminal
2R
7.1
WL/WLM
3R
40

Related parts for WLCL-TS