S29JL032H90TFI320 Spansion Inc., S29JL032H90TFI320 Datasheet - Page 27

IC, FLASH, 32MBIT, 90NS, TSOP-48

S29JL032H90TFI320

Manufacturer Part Number
S29JL032H90TFI320
Description
IC, FLASH, 32MBIT, 90NS, TSOP-48
Manufacturer
Spansion Inc.
Datasheet

Specifications of S29JL032H90TFI320

Memory Type
Flash
Memory Size
32Mbit
Memory Configuration
4M X 8 / 2M X 16
Ic Interface Type
CFI, Parallel
Access Time
90ns
Supply Voltage Range
2.7 To 3.6 V
Memory Case Style
TSOP
Data Bus Width
8 bit, 16 bit
Architecture
Boot Sector
Interface Type
Conventional
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.7 V
Maximum Operating Current
2 mA
Mounting Style
SMD/SMT
Operating Temperature
+ 85 C
Package / Case
TSOP-48
Rohs Compliant
YES
No. Of Pins
48
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S29JL032H90TFI320
Manufacturer:
Spansion
Quantity:
135
Part Number:
S29JL032H90TFI320
Manufacturer:
PANASONIC
Quantity:
4 314
Part Number:
S29JL032H90TFI320
Manufacturer:
SPANSION
Quantity:
20 000
8.14
August 31, 2009 S29JL032H_00_B8
8.14.1
8.14.2
8.14.3
8.14.4
Hardware Data Protection
Low V
Write Pulse “Glitch” Protection
Logical Inhibit
Power-Up Write Inhibit
The command sequence requirement of unlock cycles for programming or erasing provides data protection
against inadvertent writes (refer to
hardware data protection measures prevent accidental erasure or programming, which might otherwise be
caused by spurious system level signals during V
noise.
When V
power-up and power-down. The command register and all internal program/erase circuits are disabled, and
the device resets to the read mode. Subsequent writes are ignored until V
system must provide the proper signals to the control pins to prevent unintentional writes when V
than V
Noise pulses of less than 5 ns (typical) on OE#, CE# or WE# do not initiate a write cycle.
Write cycles are inhibited by holding any one of OE# = V
CE# and WE# must be a logical zero while OE# is a logical one.
If WE# = CE# = V
edge of WE#. The internal state machine is automatically reset to the read mode on power-up.
LKO
CC
CC
.
Write Inhibit
is less than V
IL
and OE# = V
LKO
D a t a
, the device does not accept any write cycles. This protects data during V
Figure 8.3 Secured Silicon Sector Protect Verify
IH
Table 10.1 on page 37
Silicon Sector address
Silicon Sector address
S h e e t
during power up, the device does not accept commands on the rising
Write 40h to Secure
Read from Secure
A1 = 1, A0 = 0
A1 = 1, A0 = 0
Write 60h to
any address
with A6 = 0,
with A6 = 0,
RESET# =
Wait 1 ms
S29JL032H
V
START
IH
or V
ID
CC
power-up and power-down transitions, or from system
IL
Secure Silicon Sector
Secure Silicon Sector
Secure Silicon Sector
Remove V
for command definitions). In addition, the following
, CE# = V
If data = 00h,
is unprotected.
If data = 01h,
from RESET#
Protect Verify
is protected.
Write reset
command
complete
IH
IH
or V
or WE# = V
ID
CC
is greater than V
IH
. To initiate a write cycle,
LKO
CC
. The
is greater
CC
27