LM93CIMT National Semiconductor, LM93CIMT Datasheet - Page 66

no-image

LM93CIMT

Manufacturer Part Number
LM93CIMT
Description
Microprocessor Support IC
Manufacturer
National Semiconductor
Datasheets

Specifications of LM93CIMT

Peak Reflow Compatible (260 C)
No
Supply Voltage Max
3.6V
Leaded Process Compatible
No
Supply Voltage Min
3V
Operating Temperature Min
0��C
Package / Case
56-TSSOP
Operating Temperature Max
85°C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM93CIMT
Manufacturer:
NSC
Quantity:
101
Part Number:
LM93CIMT
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM93CIMT/NOPB
Manufacturer:
Intersil
Quantity:
169
Part Number:
LM93CIMTX
Quantity:
179
Part Number:
LM93CIMTX
Manufacturer:
TI/德州仪器
Quantity:
20 000
Part Number:
LM93CIMTX/NOPB
Manufacturer:
NSC
Quantity:
400
www.national.com
Register
Address
Register
Address
16.0 Registers
16.8.8 Register C3h Zones 1/2 MinPWM and Hysteresis
16.8.9 Register C4h Zones 3/4 MinPWM and Hysteresis
C3h
C4h
Read/
Read/
Write
Write
R/W
R/W
3:0
7:4
3:0
7:4
Bit
Bit
MinPWM and
MinPWM and
Hysteresis
Hysteresis
Zones 1/2
Zones 3/4
Register
Register
(Continued)
Name
Name
MinPWM
MinPWM
FC_TH
FC_TH
Name
Name
Bit 7
Bit 7
R/W
R/W
R/W
R/W
R/W
R/W
Bit 6
Bit 6
This field sets the amount of hysteresis (in degrees
C) that is used by the auto-fan control for zones 1
and 2. This should be set greater than 0 to avoid
unwanted oscillation between two steps in the look-up
table.
This field determines the duty cycle that the auto-fan
control requests for zones 1 and 2 if the temperature
for the given zone falls below the programmed base
temperature for that zone. This field accepts 16
possible values that are mapped to duty cycles
according the table in the Auto-Fan Control section.
This field sets the amount of hysteresis (in degrees
C) that is used by the auto-fan control for zones 3
and 4. This should be set greater than 0 to avoid
unwanted oscillation between two steps in the look-up
table.
This field determines the duty cycle that the auto-fan
control requests for zones 3 and 4 if the temperature
for the given zone falls below the programmed base
temperature for that zone. This field accepts 16
possible values that are mapped to duty cycles
according the table in the Auto-Fan Control section.
MinPWM
MinPWM
Bit 5
Bit 5
66
Bit 4
Bit 4
Description
Description
Bit 3
Bit 3
Bit 2
Bit 2
FC_TH
FC_TH
Bit 1
Bit 1
Bit 0
Bit 0
Default
Default
Value
Value
N/D
N/D