3RT10152BB41 SIEMENS, 3RT10152BB41 Datasheet - Page 50

CONTACTOR, AC-3, 3KW/400V

3RT10152BB41

Manufacturer Part Number
3RT10152BB41
Description
CONTACTOR, AC-3, 3KW/400V
Manufacturer
SIEMENS
Datasheet

Specifications of 3RT10152BB41

Operating Voltage
24VDC
Switching Power Ac3
3kW
Switching Current Ac1
18A
Switching Current Ac3
7A
No. Of Poles
3
Contacts
1NO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Contact Configuration
1NO
3RA14 Contactor Assemblies for Wye-Delta Starting
3RA14 complete units, 3 ... 75 kW
1) Coil operating range
1) Use the 3RA19 32-2B base plate for this configuration.
2) Generally possible. If a solid-state time-delay auxiliary switch block is
3) Not part of the scope of supply of the preassembled contactor
4) See Monitoring and Control Devices: 3RP, 7PV timing relays -> 3RP15
Size S2-S2-S0 · up to 30 kW
Accessories
15
16
17
18
19
4
7
3/50
Mountable accessories (to be ordered separately):
at 50 Hz: 0.8 ... 1.1 x U
mounted onto the front of K3, a standard auxiliary switch block can only
be mounted onto the side.
assemblies; can be ordered as an accessory.
timing relays in 22.5 mm industrial enclosure.
Mechanical interlock, lateral
Depth compensation required
K3: 1.5 mm; K2: 0 mm
Solid-state time-delay
auxiliary switch block, front
Auxiliary switch block, lateral
Surge suppressors
3-phase line-side terminal
Three-phase busbar
Push-in lug
screw mounting
3RA13, 3RA14 Contactor Assemblies
Siemens LV 1 · 2006
3)
for timing relay
s
; at 60 Hz: 0.85 ... 1.1 x U
Rated data AC-3
Opera-
tional
current I
up to
400 V
A
50 / 65
50 / 65
AC operation, 50/60 Hz
DC operation
1)
2)
e
Ratings of induction motors at
50 Hz and
230 V 400 V
kW
19.6
19.6
Order No.
3RA19 24-2B
3RT19 26-2G...
3RH19 21-1EA..
3RT19 26-1....
3RT19 36-1....
3RV19 35-5A
3RV19 35-1A
3RP19 03
kW
22 / 30
22 / 30
s
.
500 V 690 V
kW
35
35
Page
3/43
3/117
3/114
3/119,
3/120
3/53
3/53
4)
kW
34
34
The fully wired and tested contactor assembly includes the following
components:
Rated control
supply voltage
U
V
230 AC
24 AC
110 AC
24 DC
s
Individual parts
10
11
1)
1 2
8
9
6
3
Contactors, 22/30 kW
Timing relay, lateral
Auxiliary switch block with
1 unassigned NO contact
Auxiliary switch block for
local control
2 units
3 units
Base plate
Installation kit
The installation kit contains the star jumper on the top and the wiring
jumper on the bottom for connecting the main conducting paths.
DT
}
C
C
}
Fully wired and tested contactor
assemblies
Order No.
3RA14 34-8XC21-1AL2
3RA14 34-8XC21-1AC2
3RA14 34-8XC21-1AG2
3RA14 34-8XC21-1BB4
* You can order this quantity or a multiple thereof.
Order No.
K1
3RT10 34 3RT10 34 3RT10 26 3/14
3RP15 74-1N.30
3RH19 21-1CA10
3RH19 21-1CA01
3RH19 21-1CA10
3RA19 32-2E
3RA19 33-2C
Price
per PU
K3
PU
(UNIT,
SET, M)
1 1 unit 101
1 1 unit 101
1 1 unit 101
1 1 unit 101
The connecting
leads are not
shown.
PS*
K2
PG Weight
per PU
approx.
kg
Page
4)
3/112
3/112
3/53
3/53
3.070
3.140
3.120
4.520

Related parts for 3RT10152BB41