Technical data
General
Environment
Cabling capacity
* Ingress protection provided by E22 component fitted to a suitable enclosure.
Contact ratings – Contact blocks
AC15 duty (AC11 to IEC337)
DC13 duty (DC11 to IEC337)
Standards and approvals
Terminal markings
Ingress protection – IEC529*
Protection against direct contact IEC529
Mechanical life span (no. of operations)
Operating frequency (operations per hour)
Weight
Pollution degree IEC947-1
Impulse withstand voltage IEC947-1
Operating ambient temperature – non-illuminated
Vibration resistance 10 sweeps 10 - 500Hz
Shock resistance (shock duration 18ms)
Bump resistance 6ms 1000cycles
Storage temperature
Mounting position
Operating altitude
Number of conductors
Solid, stranded or flexible – Max wire size (mm
Thermal current Ith
Insulation voltage Ui
Operating frequency limits
Adjacent contacts 'electrically separate'
Control of A.C. electromagnetic
loads
Control of D.C. electromagnets
22.5mm Pushbuttons, Indicating Lights and
22.5mm Pushbuttons
Selector Switches
E22 Series - Technical data
– UL508 (NEMA)*
– Min wire size (mm
– illuminated
50 to 60Hz
Yes
Ue
120V
240V
440V
660V
Ue
48V
120V
220V
440V
660V
10A
690V
48V
24V
2
2
)
)
VA
480
720
960
880
990
W
192
288
120
110
110
66
Contact
blocks
IEC947-5-1, IEC337-1, BS4794, VDE0660, UL508, CSA22.2 no. 14, Lloyds
EN50013 (BS5581)
IP20
3,000,000
6,000
13g (single)
22g (double)
3
4kV
–20 to +60 C
25g
–40 to +80 C
Any
2000m
2
2.5
0.75
Ie
10A
6A
4A
2A
1.5A
Ie
8A
6A
1A
0.5A
0.25A
0.1A
www.eatonelectrical.com
Short circuit co-ordination
UL and CSA ratings
Contact operation
Low power switching
(Operating under normal environmental conditions)
Conditional short circuit current Ig
Fuse type BS88 type gG
Maximum rated voltage
Switching capacity
Normally open (N.O.)
Normally closed (N.C.)
Minimum operational voltage (ac/dc)
Minimum operational current (ac/dc)
– Heavy pilot duty (A600)
– Heavy pilot duty (Q600)
Pushbutton
operators
IP65
Type 4, 4x, 13
5,000,000
6,000
43g
3
4kV
–20 to +60 C
–20 to +60 C
5g
30g
25g
–40 to +80 C
Any
2000m
Push/pull
operators
1P65
Type 4, 4x, 13
300,000
3,000
32g
3
4kV
–20 to +60 C
–20 to +60 C
5g
30g
25g
–40 to +80 C
Any
2000m
1kA
10A
600Vac
6A ac
0.55A dc
Slow make, break
Slow make break,
positive action
5V
1mA
Double headed
operators
1,000,000
6,000
26g
3
4kV
–20 to +60 C
–20 to +60 C
5g
30g
–40 to +80 C
Any
2000m