CB-OBS433X-02-0 ConnectBlue, CB-OBS433X-02-0 Datasheet - Page 10

no-image

CB-OBS433X-02-0

Manufacturer Part Number
CB-OBS433X-02-0
Description
SERIAL PORT ADAPTER U.FL
Manufacturer
ConnectBlue
Datasheets

Specifications of CB-OBS433X-02-0

Frequency
2.402GHz ~ 2.48GHz
Modulation Or Protocol
Bluetoothv2.1+EDR
Applications
General Purpose
Power - Output
17dBm
Sensitivity
-94dBm
Voltage - Supply
3.3 V ~ 6 V
Current - Receiving
200mA
Current - Transmitting
200mA
Data Interface
Connector, 2 x 10 Header, 2 mm Pitch
Antenna Connector
U.FL
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
809-1039
connectBlue
Copyright © 2010 connectBlue AB
* All signals are logic level UART signals (typically 0 / 3.0VDC).
** Use max 4.7kOhm as pull-down which is different to previous product generations from connectBlue.
*** Alternative signal pin recommended to use in new designs (both signal pins should be connected).
**** Available on request. Contact
The cB-0939 module has an step down DC/DC voltage regulator, which means that the current decrease if the voltage supply level is
increased.
3.3 Characteristics
12
13
14
15
16
17
18
19
20
-
-
-
-
3.3.1 Power supply
-
-
-
-
-
-
-
-
-
19
9
10
20
NOTE
Read the
6
8
9
10
11
12
13
5
18,
30***
1
36
35
2
Guidelines for Efficient and Safe Use
-
-
-
**** UART-CTS*
**** UART-TxD*
**** UART-RTS*
**** UART-RxD*
-
-
-
-
-
-
Switch-0
GREEN/Switch-1 CMOS
BLUE
UART-DTR*
UART-DSR*
Reset-n
SerialSelect-0
SerialSelect-1
VCC-3V
[connectBlue]
for more info.
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
CMOS
3.0 V
before using the modules.
In
In/Out 3
Out
In
Out
Out
In
Out
In
In
Out
Out
Out
1
4
5
6
7
8
0
9
-
20
19
-
Used for the "Connect on external signal" function, see the
Serial Port Adapter AT command Specification for more
information on the Function switch. Active low.
A secondary function is that the module will restore all factory
settings if both the Switch-1 and Switch-0 signals are low
during start up.
See the Serial Port Adapter AT command Specification for
more information on the Restoring Default Configuration
functionality.
See section
This signal is multiplexed:
GREEN:Logic Green LED Signal (see the
section). Not valid until 500ms after startup. Active low.
Switch-1: If the level on this pin is pulled-down** the unit goes
back to default serial settings. The Switch-1 input is only
active during the first 700ms after startup. The module will
restore all factory settings if both the Switch-1 and Switch-0
signals are low during start up.
See the Serial Port Adapter AT command Specification for
more information on the Restoring Default Configuration
functionality.
See section
Logic Blue LED Signal (see the
Active low.
Note:Signal will flicker at data transmission.
See section
Clear To Send. Hardware flow control. Active low.
Transmit Data. "0" : Low, "1" : High
Request To Send. Hardware flow control. Active low.
Receive Data. "0" : Low, "1" : High
Data Terminal Ready. Active low.
Data Set Ready. Active low.
Hardware reset. Active low
Control signal for external serial transceivers.
See
Control signal for external serial transceivers.
See
Regulated interface voltage for voltage level shifting, max
10mA.
Appendix Serial Interface
Appendix Serial Interface
Switch-0 Signal
GREEN/Switch-1
BLUE Signal
for design examples.
for design examples.
for design examples.
section for more info.
section for more info.
Operating status
Operating status
Page 10 of 42
section).