Frequency
30MHz ~ 2.5GHz
Number Of Mixers
1
Gain
-2dB
Noise Figure
12dB
Secondary Attributes
Up/Down Converter
Current - Supply
75mA
Voltage - Supply
2.7 V ~ 3.6 V
Package / Case
32-VFQFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
689-1089-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RF2052TR7
Manufacturer:
RFMD
Quantity:
9 200
Setting Up VCO Coarse Tuning and Loop Filter Calibration
If the user wishes to disable the VCO coarse tune calibration or enable the loop filter calibration then the following program-
ming operation will need to take place.
Two registers need to be written taking 2.6us at maximum clock speed if the course tuning is deactivated or the loop filter cal-
ibration activated. Since it is necessary to program these registers when setting the operating frequency (see next section) this
operation usually carries no overhead.
The coarse tune calibration takes approximately 50us when using a 26MHz reference clock (it will take proportionally longer if
a slower clock is used, and vice versa).
DS100630
2
Operating mode set
Default
Default
Set calibration
coarse tune?
Disable VCO
Enable loop
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or sales-support@rfmd.com.
filter cal?
mode
Yes
Yes
3
P2_CT_EN
calibration
Loop filter
Set to 00
When setting up the device it is necessary to decide
whether to deactivate the devices' internal VCO
calibration or provide the calibration information
directly. These bits are located in the PLL2x0 register
and are active by default.
It is also necessary to decide whether to activate the
loop filter calibration mode, only necessary when
operating the device over very wide band of
frequencies. These bits are also located in the PLL2x0
register. The default setting assumes an active loop
filter is used.
RF2052