CS1W-CRM21 Omron, CS1W-CRM21 Datasheet - Page 107
CS1W-CRM21
Manufacturer Part Number
CS1W-CRM21
Description
CS1 CompoNet Master
Manufacturer
Omron
Datasheet
1.CS1W-CRM21.pdf
(419 pages)
Specifications of CS1W-CRM21
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
- Current page: 107 of 419
- Download datasheet (7Mb)
Note 1: With a CJ2H-CPU6@-EIP or CJ2M-CPU3@ CPU Unit, connecting to an
Note 2: When connecting online with a SYSMAC CS1 Board, specify one of the device
Note 3: The following functions cannot be used when running the CX-Integrator on
Click the Settings Button to display the Network Settings Dialog Box for each type of
network. Details are described here for Toolbus, SYSMAC WAY, and Ethernet. Refer to
the CX-Programmer Operation Manual (Cat. No. W446) for other methods.
Toolbus
Click the Driver Tab and set the following settings as required.
Port Name:
Baud Rate:
Baud Rate Auto-Detect: Clear this selection to connect with the baud rate set on the
Ethernet network is not possible from the built-in EtherNet/IP port or an
EtherNet/IP Unit port if the network connection is set for EtherNet/IP. Always set
Ethernet or Ethernet (FINS/TCP) to connect to an Ethernet network. In addition,
connection is impossible when “USB” is selected in the network settings. Select
“Toolbus (USB port)”.
types in parentheses. CS1 Board can be selected as the network type only
when one of these device types is selected.
Windows Vista or Windows 7.
- Online connections to PLCs on Controller Link networks are not possible
- Online connections to PLCs on SYSMAC LINK networks are not
- Online connections to PLCs on SYSMAC NET networks are not possible
- Online connections to CS1 Boards in computers are not possible when
- Online connections to SYSMAC Boards in computers are not possible
- Online connections to PLCs on the network are not possible when
through a Controller Link Support Board when Controller Link is selected
as the network type.
possible through a SYSMAC LINK Support Board when SYSMAC LINK
is selected as the network type.
through a SYSMAC NET Support Board when SYSMAC NET is selected
as the network type.
"CS1 board" is selected as the network type.
when "SYSMAC Board" is selected as the network type.
FinsGateway is selected as the network type.
Select the computer’s COM port from the drop-down list.
Select the baud rate (bits/s) from the drop-down list.
computer, ignoring the baud rate of the serial port on the CPU
Unit. To disable automatic detection of the baud rate, the DIP
switch on the CPU Unit must be set as follows:
2-2-2
Procedures
2-15
Related parts for CS1W-CRM21
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
MODULE,ANALOG OUT,4CH
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
MODULE, ANALOG IN, 8CH
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Connector Cable
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
Cable Connector
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
"BATTERY,CPU,CS1 SERIES ONLY"
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
"CABLE,CS1/ CQM1-PRO01,0.1m"
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
BACKPLANE,CS1 CPU,3 SLOTS
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
"BACKPLANE,CS1 CPU,8 SLOTS"
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: