2-3
2-3-2
2-26
Uploading Network Configurations and Checking for Communications Unit Errors
!Caution Do not use this function if a node exists for something other than an OMRON
Procedure
Note
Clicking the Transfer Button is will start the transfer. Clicking the Cancel Button will
2) For Ethernet networks:
The following message will be displayed for verification.
Check to confirm that no nodes other than OMRON Ethernet Units or FinsGateway
exist in the same segment, and then click the OK Button. The dialog box will then be
displayed for selecting the data to be transferred.
Click the Transfer Button to display the following Searching Node Setting Dialog
Check the range of FINS node addresses on the Ethernet network for the applicable
If the range of addresses is unknown, select All (1 to 254), and then click the OK
Click the Cancel Button to cancel the transfer.
Ethernet Unit or FinsGateway within the same segment on Ethernet, and when the
Ethernet network system is in operation. When an Ethernet network configuration
cancel it.
Box.
nodes and input the minimum and maximum values of the range. Then click the OK
Button. The transfer will start.
Button.
If the default settings are use for the minimum and maximum nodes (1 for both),
the network configuration will be uploaded only from the node with node address
1. Always set the minimum and maximum node addresses.
If nodes in the specified range do not exist, it will take 20 seconds per node to
search for it. If All (1 to 254) is selected, it will take up to approximately 85 minutes
for the transfer to be completed. The transfer will also take longer if a maximum
address is entered that is higher than any of the existing node address.