ZL30106QDG Zarlink, ZL30106QDG Datasheet - Page 25

no-image

ZL30106QDG

Manufacturer Part Number
ZL30106QDG
Description
SONET/SDH/PDH Network Interface 64-Pin TQFP
Manufacturer
Zarlink
Datasheet

Specifications of ZL30106QDG

Package
64TQFP
Power Supply Type
Analog
Typical Supply Current
68(Max) mA
Typical Operating Supply Voltage
1.8|3.3 V
Minimum Operating Supply Voltage
1.62 V
Maximum Operating Supply Voltage
3.63 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ZL30106QDG
Manufacturer:
ZARLINK
Quantity:
600
Part Number:
ZL30106QDG1
Manufacturer:
ZARLINK
Quantity:
600
Company:
Part Number:
ZL30106QDG1
Quantity:
120
4.5.2
In the automatic mode of operation (MODE_SEL1:0 = 11), the ZL30106 automatically selects a reference input that
is not out-of-range (REF_OOR=0, see Figure 3). The state machine can only select REF0 or REF1. REF2 cannot
be selected in the Automatic mode. See Figure 14.
If the current reference (REF0 or REF1) used for synchronization fails, the state machine will switch to the other
reference. If both references fail then the ZL30106 enters the Holdover mode without switching to another
reference. When the ZL30106 comes out of reset or when REF2 is the current reference when the ZL30106 is put
in the Automatic mode, then REF0 has priority over REF1. Otherwise there is no preference for REF0 or REF1
which is referred to as non-revertive reference selection.
REF_OOR = reference out of range, see Figure 3
Automatic Reference Switching
REF_SEL
LOCK
Note: LOCK pin behaviour depends on phase and frequency offset of REF1.
Figure 14 - Reference Selection in Automatic Mode (MODE_SEL=11)
Figure 13 - Reference Switching in Normal Mode
Reference
REF0
REF0
RST && REF_OOR0=0
Zarlink Semiconductor Inc.
REF1
REF_OOR0=0
REF_OOR0=0 &&
REF_OOR0=1 &&
ZL30106
REF_OOR1=1
REF_OOR1=0
Reference
REF2
25
Lock Time
REF_OOR0=1 && REF_OOR1=0
Reference
REF1
RST && REF_OOR0=1 && REF_OOR1=0
Data Sheet

Related parts for ZL30106QDG