ACS302-5T3 STMicroelectronics, ACS302-5T3 Datasheet - Page 4

IC AC SWITCH ARRAY 3LINE 20-SOIC

ACS302-5T3

Manufacturer Part Number
ACS302-5T3
Description
IC AC SWITCH ARRAY 3LINE 20-SOIC
Manufacturer
STMicroelectronics
Series
ASD™r
Datasheet

Specifications of ACS302-5T3

Triac Type
Logic - Sensitive Gate
Mounting Type
Surface Mount
Configuration
Array
Current - Hold (ih) (max)
45mA
Voltage - Off State
500V
Current - Gate Trigger (igt) (max)
5mA
Current - Non Rep. Surge 50, 60hz (itsm)
7.3A, 7.6A
Current - On State (it (rms)) (max)
200mA
Voltage - Gate Trigger (vgt) (max)
900mV
Package / Case
20-SOIC (0.300", 7.50mm Width)
Current - On State (it (rms) (max)
200mA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
497-3114-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACS302-5T3
Manufacturer:
STMicroelectronics
Quantity:
480
Part Number:
ACS302-5T3
Manufacturer:
ST
0
Part Number:
ACS302-5T3-TR
Manufacturer:
ST
0
ACS302-5T3
HIGH INDUCTIVE SWITCH-OFF OPERATION
At the end of the last conduction half-cycle, the load current reaches the holding current level I
ACS™ switch turns off. Because of the inductance L of the load, the current flows through the avalanche
diode D and decreases linearly to zero. During this time, the voltage across the switch is limited to the
clamping voltage V
The energy stored in the inductance of the load depends on the holding current I
10 H); it can reach about 20 mJ and is dissipated in the clamping diode section that is especially designed
for that purpose.
Fig. 1: Turn-off operation of the ACS302 switch
with an electro valve: waveform of the pin OUT
current I
Fig. 3: Overvoltage ruggedness test circuit for
resistive and inductive loads according to
IEC61000-4-5 standard.
R = 150 , L = 5µH, V
4/8
AC LINE TRANSIENT VOLTAGE RUGGEDNESS
The ACS302 switch is able to withstand safely the AC line transient voltages either by clamping the low en-
ergy spikes or by breaking over under high energy shocks.
The test circuit of the figure 3 is representative of the final ACS™ application and is also used to stress the
ACS switch according to the IEC61000-4-5 standard conditions. Thanks to the load, the ACS™ switch
withstands the voltage spikes up to 2 kV above the peak line voltage. It will break over safely even on resis-
tive load where the turn on current rise is high as shown on figure 4. Such non repetitive test can be done
10 times on each AC line voltage polarity.
AC LINE & GENERATOR
SURGE VOLTAGE
OUT
& voltage V
CL
.
PP
OUT
= 2kV.
V
R
AC
.
+ V
PP
G
L
OUT
COM
ACS302
Fig. 2: ACS302 switch static characteristic.
Fig. 4: Current and Voltage of the ACS™ during
IEC61000-4-5 standard test with R = 150 , L = 5 H
& V
PP
= 2kV.
I
H
I
OUT
H
and the inductance (up to
V
CL
H
, and the
V
OUT

Related parts for ACS302-5T3