Because data is not transferred to the host, TC
cannot be used to terminate this command. By
setting the EC bit to "1", an implicit TC will be
issued to the FDC. This implicit TC will occur when
of 0 will verify 256 sectors). This command can
also be terminated by setting the EC bit to "0" and
the EOT value equal to the final sector to be
checked.
Note: If MT is set to "1" and the SC value is greater than the number of remaining formatted sectors on
Side 0, verifying will continue on Side 1 of the disk.
the SC value has decremented to 0 (an SC value
MT
0
0
0
0
1
1
1
1
If
EC
0
0
1
1
0
0
1
1
EC
SC = DTL
EOT ≤ # Sectors Per Side
SC = DTL
EOT > # Sectors Per Side
SC ≤ # Sectors Remaining AND
EOT ≤ # Sectors Per Side
SC > # Sectors Remaining OR
EOT > # Sectors Per Side
SC = DTL
EOT ≤ # Sectors Per Side
SC = DTL
EOT > # Sectors Per Side
SC ≤ # Sectors Remaining AND
EOT ≤ # Sectors Per Side
SC > # Sectors Remaining OR
EOT > # Sectors Per Side
is
Table 24 - Verify Command Result Phase
set
SC/EOT VALUE
to
"0",
58
DTL/SC should be programmed to 0FFH. Refer to
Table 23 and Table 24 for information concerning
the values of MT and EC versus SC and EOT
value.
Definitions:
# Sectors Per Side = Number of formatted sectors
per each side of the disk.
# Sectors Remaining = Number of formatted
sectors left which can be read, including side 1 of
the disk if MT is set to "1".
Success Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
Successful Termination
Result Phase Valid
Unsuccessful Termination
Result Phase Invalid
TERMINATION RESULT