ISP1160BM01FE STEricsson, ISP1160BM01FE Datasheet - Page 55

no-image

ISP1160BM01FE

Manufacturer Part Number
ISP1160BM01FE
Description
Manufacturer
STEricsson
Datasheet

Specifications of ISP1160BM01FE

Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1160BM01FE
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
ISP1160-01_7
Product data sheet
10.4.1 HcHardwareConfiguration register (R/W: 20H/A0H)
10.4 HC DMA and interrupt control registers
Table 35.
Code (Hex): 20 — read
Code (Hex): A0 — write
Bit
2
1
0
HcRshPortStatus[1:2] register: bit description
Symbol
PSS
PES
CCS
Rev. 07 — 29 September 2009
Description
On read—PortSuspendStatus: This bit indicates whether the port is
suspended or in the resume sequence. It is set by a SetSuspendState
write and cleared when PortSuspendStatusChange is set at the end of
the resume interval. This bit cannot be set if CurrentConnectStatus is
cleared. This bit is also cleared when PortResetStatusChange is set at
the end of the port reset or when the HC is placed in the USBResume
state. If an upstream resume is in progress, it should propagate to the
HC.
0 — port is not suspended
1 — port is suspended
On write—SetPortSuspend: The HCD sets bit PortSuspendStatus by
writing a logic 1 to this bit. Writing a logic 0 has no effect. If
CurrentConnectStatus is cleared, this write does not set
PortSuspendStatus; instead it sets ConnectStatusChange. This
informs the driver that it attempted to suspend a disconnected port.
On read—PortEnableStatus: This bit indicates whether the port is
enabled or disabled. The Root Hub may clear this bit when an
overcurrent condition, disconnect event, switched-off power, or
operational bus error such as babble is detected. This change also
causes PortEnabledStatusChange to be set. The HCD sets this bit by
writing SetPortEnable and clears it by writing ClearPortEnable. This bit
cannot be set when CurrentConnectStatus is cleared. This bit is also
set at the completion of a port reset when ResetStatusChange is set or
port is suspended when SuspendStatusChange is set.
0 — port is disabled
1 — port is enabled
On write—SetPortEnable: The HCD sets PortEnableStatus by writing
a logic 1. Writing a logic 0 has no effect. If CurrentConnectStatus is
cleared, this write does not set PortEnableStatus, but instead sets
ConnectStatusChange. This informs the driver that it attempted to
enable a disconnected port.
On read—CurrentConnectStatus: This bit reflects the current state of
the downstream port.
0 — no device connected
1 — device connected
On write—ClearPortEnable: The HCD writes a logic 1 to this bit to
clear bit PortEnableStatus. Writing a logic 0 has no effect.
CurrentConnectStatus is not affected by any write.
Remark: This bit always reads logic 1 when the attached device is
nonremovable (DeviceRemoveable[NDP]).
…continued
Embedded USB host controller
ISP1160/01
© ST-ERICSSON 2009. All rights reserved.
55 of 87

Related parts for ISP1160BM01FE