ADC12H034CIMSA/NOPB National Semiconductor, ADC12H034CIMSA/NOPB Datasheet - Page 38

ADC 12BIT W/S&H +SIGN 24-SSOP

ADC12H034CIMSA/NOPB

Manufacturer Part Number
ADC12H034CIMSA/NOPB
Description
ADC 12BIT W/S&H +SIGN 24-SSOP
Manufacturer
National Semiconductor
Datasheet

Specifications of ADC12H034CIMSA/NOPB

Number Of Bits
12
Data Interface
NSC MICROWIRE™, Serial
Number Of Converters
4
Power Dissipation (max)
33mW
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-SSOP (0.200", 5.30mm Width)
Number Of Elements
1
Architecture
SAR
Input Polarity
Unipolar
Input Type
Voltage
Rated Input Volt
5V
Differential Input
Yes
Power Supply Requirement
Analog and Digital
Single Supply Voltage (typ)
5V
Single Supply Voltage (min)
4.5V
Single Supply Voltage (max)
5.5V
Dual Supply Voltage (typ)
Not RequiredV
Dual Supply Voltage (min)
Not RequiredV
Dual Supply Voltage (max)
Not RequiredV
Power Dissipation
500mW
Differential Linearity Error
±1LSB
Integral Nonlinearity Error
±1LSB
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
24
Package Type
SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
ADC12H034CIMSA
www.national.com
'variables
'
'SET CS# HIGH
OUT
OUT
OUT
OUT
10
LINE INPUT “DI data for ADC12038 (see Mode Table on data sheet)”; DI$
INPUT “ADC12038 output word length (8,9,12,13,16 or 17)”; DOL
20
'SET CS# HIGH
OUT
OUT
OUT
'SET CS# LOW
OUT
OUT
OUT
DO$=
FOR N=1 TO 8
NEXT N
IF DOL>8 THEN
END IF
OUT
FOR N=1 TO 500
NEXT N
PRINT DO$
INPUT “Enter “C” to convert else “RETURN” to alter DI data”; s$
IF s$=“C” OR s$=“c” THEN
ELSE
END IF
END
OUT &H3FC, (&H1 OR INP(&H3FC))
OUT &H3FC, (&HFD AND INP(&H3FC))
Temp$=MID$(DI$,N,1)
IF Temp$=“0” THEN
ELSE OUT &H3FC, (&HFE AND INP(&H3FC))
END IF
OUT &H3FC, (&H2 OR INP(&H3FC))
IF
END IF
OUT &H3FC, (&H1 OR INP(&H3FC))
OUT &H3FC, (&HFD AND INP(&H3FC))
FOR N=9 TO DOL
OUT &H3FC, (&H1 OR INP(&H3FC))
OUT &H3FC, (&HFD AND INP(&H3FC))
OUT &H3FC, (&H2 OR INP(&H3FC))
IF (INP(&H3FE) AND &H10)=&H10 THEN
ELSE
END IF
NEXT N
GOTO 20
GOTO 10
OUT &H3FC,(&H1 OR INP(&H3FC))
DO$=DO$+“0”
ELSE
DO$=DO$+“1”
DO$=DO$+“0”
DO$=DO$+“1”
&H3FC, (&H2 OR INP (&H3FC))
&H3FC, (&HFE AND INP(&H3FC))
&H3FC, (&HFD AND INP(&H3FC))
&H3FC, (&HEF AND INP(&H3FC))
&H3FC, (&H2 OR INP (&H3FC))
&H3FC, (&HFE AND INP(&H3FC))
&H3FC, (&HFD AND INP(&H3FC))
&H3FC, (&H2 OR INP (&H3FC))
&H3FC, (&H1 OR INP(&H3FC))
&H3FC, (&HFD AND INP(&H3FC))
(INP(&H3FE) AND 16)=16 THEN
&H3FC, (&HFA AND INP(&H3FC))
“ ”
DOL=Data Out word length, DI=Data string for ADC DI input,
DO=ADC result string
'set RTS HIGH
'set DTR LOW
'set RTS LOW
'set B4 low
'set RTS HIGH
'set DTR LOW
'set RTS LOW
'set RTS HIGH
'set DTR HIGH
'set RTS LOW
'SET DTR HIGH
'SCLK low
'out DI
'SCLK high
'input DO
'SET DTR HIGH
'SCLK low
'SET DTR HIGH
'SCLK low
'SCLK high
'SCLK low and DI high
'reset DO variable
Code Listing:
38

Related parts for ADC12H034CIMSA/NOPB