IC TOUCH SCREEN CTLR 12-WLP

MAX11800EWC+T

Manufacturer Part NumberMAX11800EWC+T
DescriptionIC TOUCH SCREEN CTLR 12-WLP
ManufacturerMaxim Integrated Products
TypeResistive
MAX11800EWC+T datasheet
 


Specifications of MAX11800EWC+T

Touch Panel Interface4-WireNumber Of Inputs/keys1 TSC
Resolution (bits)12 bData InterfaceSerial, SPI™
Data Rate/sampling Rate (sps, Bps)105kVoltage - Supply1.7 V ~ 3.6 V
Operating Temperature-40°C ~ 85°CMounting TypeSurface Mount
Package / Case12-WLPVoltage Supply SourceSingle Supply
Sampling Rate (per Second)105kResolution11 bits
Interface TypeI2C, SPISupply Voltage (max)3.6 V
Supply Voltage (min)1.7 VConversion Rate34.4 KSPs
Maximum Operating Temperature+ 85 CMinimum Operating Temperature- 40 C
Mounting StyleSMD/SMTLead Free Status / RoHS StatusLead free / RoHS Compliant
Other namesMAX11800EWC+T
MAX11800EWC+TTR
  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Page 31
32
Page 32
33
Page 33
34
Page 34
35
Page 35
36
Page 36
37
Page 37
38
Page 38
39
Page 39
40
Page 40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
Page 32/59

Download datasheet (989Kb)Embed
PrevNext
Low-Power, Ultra-Small Resistive Touch-Screen
Controllers with I
Measurement Operations
In autonomous conversion, the MAX11800/MAX11801
idle in TDM until a touch event occurs. The
MAX11800/MAX11801 begin an automated sequence
of measurements as defined by the configuration regis-
ter 0x08h.
The MAX11800/MAX11801 tag and log the data into the
FIFO once a measurement is taken. If a touch is still pre-
sent, the devices continue to idle in a LPM until the time,
as set by the configuration settings, expires. If no touch is
present at the expiration of the time set by the configura-
tion settings, the MAX11800/MAX11801 return to TDM to
await the next panel touch.
All measurement operations occur without any interven-
tion from the AP. The MAX11800/MAX11801 issue inter-
rupts when new data is available in the internal FIFO. The
device clears the interrupt when all data is read back.
The AP controls the readback of measurement data as
the data becomes available.
Combined Commands
In autonomous conversion mode, the MAX11800/
MAX11801 automatically perform the combined com-
mand defined in the configuration register. The devices
continuously scan for panel touch events. Between
scans, the devices idle in a low-power mode according
to the present touch status.
Clear-on-Read Interrupt Mode
The MAX11800/MAX11801 control the progression
through modes in clear-on-read mode. When the panel
touch is present, the MAX11800/MAX11801 return to a
BEGINNING OF TOUCH EVENT
PANEL
TOUCH
DATA WRITTEN TO FIFO,
INTERRUPT ISSUED
TIRQ
TDM
t
INIT
READBACK OPERATIONS ARE NOT SHOWN, INDICATED BY THE CLEARING OF THE AP-INITIATED INTERRUPT.
WAIT TIME BETWEEN TOUCH DETECTION AND INITIAL SCAN (t
SCAN DURATION (t
) IS A FUNCTION OF THE SCAN TYPE AND CONFIGURATION SETTINGS.
SD
SCAN PERIOD (t
) IS CONTROLLED BY CONFIGURATION SETTINGS.
SP
Figure 15. Clear-on-Read Interrupt Operation—MAX11800/MAX11801
32
______________________________________________________________________________________
2
C/SPI Interface
timed high-impedance LPM to minimize current, after
the data tagging operations are complete. The
MAX11800/MAX11801 idle in LPM until it is time to per-
form the next required scan, determined by the config-
uration register settings. When a touch is not present at
the end of a measurement, the device returns to idle in
TDM. In TDM, the device waits until a touch is detected
before initiating another set of autonomous measure-
ments.
The MAX11800/MAX11801 adopt a clear-on-interrupt
protocol (CORINT) when in autonomous conversion
mode. Between touch events, the devices idle in a low-
power TDM state. Upon detection of a touch, the
devices begin a sequence of automated measure-
ments. Each time a qualifying measurement is complet-
ed, the data for that measurement is written to the
internal FIFO. Qualifying measurements are measure-
ments that indicate the beginning and end of a touch
event, which meet aperture requirements (see the
Aperture Range Requirements section).
TIRQ issues an interrupt once a qualifying measure-
ment is completed and logged into the FIFO indicating
that new data is available for the AP to read back. The
MAX11800/MAX11801 continue to perform measure-
ments as required by the configuration settings.
Program the AP to service the interrupt immediately to
avoid a FIFO overflow and loss of data. TIRQ remains
asserted until all unread FIFO data has been read back
to the AP. The AP confirms that readback is complete
either by monitoring TIRQ or by monitoring the data
event tags embedded in the data for end-of-FIFO.
(ETAG = 11b). See Figure 15.
AP READBACK,
INTERRUPT CLEARED
LPM
ACM SCAN
ACM SCAN
ETAG = 00
ETAG = 01
t
t
SD
SP
) IS SPECIFIED BY CONFIGURATION SETTINGS.
INIT
END OF TOUCH EVENT
INTERRUPT IS HELD PENDING
AP READBACK (FIFO STORES DATA)
SCAN
BLOCK
LPM
TDM
ACM SCAN
ETAG = 10
ACM = AUTONOMOUS CONVERSION MODE