Specifications of K4H561638J-LCCC000

Organization
16Mx16
Density
256Mb
Address Bus
15b
Access Time (max)
650ps
Maximum Clock Rate
400MHz
Operating Supply Voltage (typ)
2.6V
Package Type
TSOP-II
Operating Temp Range
0C to 70C
Operating Supply Voltage (max)
2.7V
Operating Supply Voltage (min)
2.5V
Supply Current
180mA
Pin Count
66
Mounting
Surface Mount
Operating Temperature Classification
Commercial
Lead Free Status / Rohs Status
Compliant
21.0 Component Notes
10. The output timing reference voltage level is V
11. tHZ and tLZ transitions occur in the same access time windows as valid data transitions. These parameters are not referenced to
12. The maximum limit for this parameter is not a device limit. The device will operate with a greater value for this parameter, but sys
13. The specific requirement is that DQS be valid (HIGH, LOW, or at some point on a valid transition) on or before this CK edge. A
14. A maximum of eight AUTO REFRESH commands can be posted to any given DDR SDRAM device.
15. For command/address input slew rate ≥ 1.0 V/ns
16. For command/address input slew rate ≥ 0.5 V/ns and < 1.0 V/ns
K4H560438J
K4H560838J
K4H561638J
1. All voltages referenced to V
2. Tests for ac timing, IDD, and electrical, ac and dc characteristics, may be conducted at nominal reference/supply voltage levels,
3. Figure 1 represents the timing reference load used in defining the relevant timing parameters of the part. It is not intended to be
4. AC timing and IDD tests may use a V
5. The ac and dc input level specifications are as defined in the SSTL_2 Standard (i.e., the receiver will effectively switch as a result
6. Inputs are not recognized as valid until V
7. Enables on.chip refresh and address counters.
8. IDD specifications are tested after the device is properly initialized.
9. The CK/CK input reference level (for timing referenced to CK/CK) is the point at which CK and CK cross; the input reference level
but the related specifications and device operation are guaranteed for the full voltage range specified.
either a precise representation of the typical system environment nor a depiction of the actual load presented by a production
tester. System designers will use IBIS or other simulation tools to correlate the timing reference load to a system environment.
Manufacturers will correlate to their production test conditions (generally a coaxial transmission line terminated at the tester elec-
tronics).
V
mal use conditions. The minimum slew rate for the input signals is 1 V/ns in the range between V
of the signal crossing the ac input level and will remain in that state as long as the signal does not ring back above (below) the dc
input LOW (HIGH) level.
recognized as LOW.
for signals other than CK/CK, is V
a specific voltage level but specify when the device output is no longer driving (HZ), or begins driving (LZ).
tem performance (bus turnaround) will degrade accordingly.
valid transition is defined as monotonic and meeting the input slew rate specifications of the device. when no writes were previ
ously in progress on the bus, DQS will be transitioning from High- Z to logic LOW. If a previous write was in progress, DQS could
be HIGH, LOW, or transitioning from HIGH to LOW at this time, depending on tDQSS.
REF
(or to the crossing point for CK/CK), and parameter specifications are guaranteed for the specified ac input levels under nor-
SS
.
REF
IL
.
to V
REF
IH
stabilizes. Exception: during the period before V
swing of up to 1.5 V in the test environment, but input timing is still referenced to
TT
(V
Output
.
Figure 1 : Timing Reference Load
OUT
)
18 of 24
V
TT
50Ω
30pF
REF
IL
stabilizes, CKE ≤ 0.2V
(AC) and V
Rev. 1.12 August 2008
DDR SDRAM
IH
(AC).
DDQ