EP3C16Q240C8N Altera, EP3C16Q240C8N Datasheet - Page 22

IC CYCLONE III FPGA 16K 240PQFP

EP3C16Q240C8N

Manufacturer Part Number
EP3C16Q240C8N
Description
IC CYCLONE III FPGA 16K 240PQFP
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C16Q240C8N

Number Of Logic Elements/cells
15408
Number Of Labs/clbs
963
Total Ram Bits
516096
Number Of I /o
160
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
240-MQFP, 240-PQFP
Family Name
Cyclone III
Number Of Logic Blocks/elements
15408
# I/os (max)
92
Frequency (max)
402MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
15408
Ram Bits
516096
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
0C to 85C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
240
Package Type
PQFP
For Use With
544-2601 - KIT DEV CYCLONE III LS EP3CLS200P0037 - BOARD DEV/EDUCATION ALTERA DE0544-2411 - KIT DEV NIOS II CYCLONE III ED.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant
Other names
544-2458

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C16Q240C8N
Manufacturer:
ALTERA64
Quantity:
74
Part Number:
EP3C16Q240C8N
Quantity:
1 824
Part Number:
EP3C16Q240C8N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C16Q240C8N
Manufacturer:
ALTERA
0
Part Number:
EP3C16Q240C8N
Manufacturer:
ALTERA
0
Part Number:
EP3C16Q240C8N
Manufacturer:
ALTERA
Quantity:
100
Part Number:
EP3C16Q240C8N
0
Page 22
Table 8. Requirement and Behavior of Device during Various Power-up Stages
Pre-Power Up
V
POR
CC
Ramp
Stages
f
After the Cyclone III device enters user mode, the POR circuit continues to monitor
the VCCINT and VCCA pins so that a brown-out condition during user mode can be
detected. If the V
mode, the POR circuit resets the device. The POR circuit does not reset the device if
the V
For more information about power-on reset, refer to the
Reset in Cyclone III Devices
Signals can be driven into
Cyclone III I/O pins, dedicated
inputs and dedicated clock pins
without damaging the device.
Determine the required POR time
for your device; fast POR (3 ms to
9 ms) or standard POR (50 ms to
200 ms). Selection is determined
by
Can support any power-up
sequence of supplies.
V
required. V
configuration pins (1, 6, 7, and 8)
are required.
Supplies must meet ramp rate
according to required POR; 50 µs
to 3 ms for fast POR or 50 ms for
standard POR. Fast POR is used
when Cyclone III device is
required to wake up quickly to
begin operation. Select POR using
MSEL
Configuring Cyclone III Devices
chapter in volume 1 of the
Cyclone III Device Handbook.
V
operating voltage level.
If maximum V
be met, use an external
component to hold
until the power supplies have
reached their minimum
recommended operating levels.
Else, the device may not configure
properly and enter user mode.
Maintain V
C C IO
CC
MSEL
ramp must be monotonic.
CCIO
, V
pin settings. Refer to the
C C IN T
pins setting.
voltage sags during user mode.
Requirement
C C
C CI O
, and V
ramp to desired
C C
for banks with
ramp time cannot
CCINT
nCONFIG
C C A
are
and V
chapter in volume 1 of the Cyclone III Device Handbook.
low
CCA
voltage sags below the POR trip point during user
Not applicable
Output buffers tri-stated for all conditions, for example:
Exception for configuration pins, which are expected to drive
out during power-up cycle. No hot socketing circuit for these
pins.
No current path exists from I/O pin to V
hot-socketing circuit is enabled. Refer to the
and Power-On Reset
Device Handbook for leakage or driving current during
hot-socketing.
Safe from latch-up, no low-impedance path from V
that may result in large current passing through the path.
Output buffers remain tri-stated.
POR circuit keeps device in reset state until all V
have stabilized and reached acceptable levels before
configuration is triggered.
when V
if the I/O pad voltage is higher than V
sudden voltage spikes (overshoot) during hot-socketing.
Setup
CC I O
is powered before V
chapter in volume 1 of the Cyclone III
Behavior
Hot Socketing and Power-On
© November 2008 Altera Corporation
C C I N T
Board Design Considerations
C C IN T
CC I O
or V
Hot Socketing
CC
C CI O
supplies
C C
, as
to GND