E2E2-X10MB1-M1 Omron, E2E2-X10MB1-M1 Datasheet - Page 3

Proximity Sensors With M12 Connector

E2E2-X10MB1-M1

Manufacturer Part Number
E2E2-X10MB1-M1
Description
Proximity Sensors With M12 Connector
Manufacturer
Omron
Type
Inductive Proximity Sensorr
Datasheet

Specifications of E2E2-X10MB1-M1

Maximum Operating Temperature
+ 70 C
Supply Voltage
24 V
Operating Supply Voltage
10 V to 55 V
Mounting Style
Panel
Sensing Distance
10 mm
Minimum Operating Temperature
- 25 C
Features
NO
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
E2E2-X@C@ DC 3-Wire Models
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
*2. A full-wave rectification power supply of 24 VDC
Item
Sensing distance
Set distance
Differential travel
Sensing object
Standard sensing object
Response frequency *1
Power supply voltage (op-
erating voltage range) *2
Leakage current
Control
output
Indicators
Operation mode
(with sensing object ap-
proaching)
Protection circuits
Ambient temperature
Ambient humidity
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
(destruction)
Shock resistance
(destruction)
Degree of protection
Connection method
Weight (packed state)
Materi-
als
Accessories
a set distance of half the sensing distance.
Load current
Residual voltage 2 V max. (Load current: 200 mA, Cable length: 2 m)
Case
Sensing surface PBT
Clamping nuts
Toothed washer Zinc-plated iron
Shielding
http://www.ia.omron.com/
Model
Size
2 mm±10%
0 to 1.6 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on
page 5.)
Iron,
12 × 12 × 1 mm
1.5 kHz
12 to 24 VDC (10 to 55 VDC), ripple (p-p): 10% max.
13 mA max.
NPN open-collector output, 200 mA max. (55 VDC max.)
Operation indicator (red)
C1 Models: NO
C2 Models: NC
Reverse polarity protection, Surge absorber, Load short-circuit protection
Operating/Storage: −40 to 85°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
1,000 m/s
IEC IP67, in-house standard for oil resistance
Pre-wired Models (Standard cable length: 2 m) and Connector Models
Approx. 75 g
Brass
Nickel-plated brass
Instruction sheet
E2E2-X2C@
Shielded
2
±
10 times each in X, Y, and Z directions
20% (average value) can be used.
M12
5 mm±10%
0 to 4 mm
Iron,
15 × 15 × 1 mm
400 Hz
Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
E2E2-X5MC@
Unshielded
5 mm±10%
0 to 4 mm
Iron,
18 × 18 × 1 mm
600 Hz
Approx. 160 g
E2E2-X5C@
Shielded
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
M18
E2E2-X10MC@
10 mm±10%
0 to 8 mm
Iron,
30 × 30 × 1 mm
200 Hz
Unshielded
10 mm±10%
0 to 8 mm
Iron,
30 × 30 × 1 mm
400 Hz
Approx. 220 g
E2E2-X10C@
Shielded
M30
100 Hz
E2E2-X18MC@
18 mm±10%
0 to 14 mm
Iron,
54 × 54 × 1 mm
Unshielded
E2E2