E2E2-X10MB1-M1 Omron, E2E2-X10MB1-M1 Datasheet - Page 4

Proximity Sensors With M12 Connector

E2E2-X10MB1-M1

Manufacturer Part Number
E2E2-X10MB1-M1
Description
Proximity Sensors With M12 Connector
Manufacturer
Omron
Type
Inductive Proximity Sensorr
Datasheet

Specifications of E2E2-X10MB1-M1

Maximum Operating Temperature
+ 70 C
Supply Voltage
24 V
Operating Supply Voltage
10 V to 55 V
Mounting Style
Panel
Sensing Distance
10 mm
Minimum Operating Temperature
- 25 C
Features
NO
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
E2E2-X@Y@ AC 2-Wire Models
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least −25°C to 85°C.
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of 5
Item
Sensing distance
Set distance
Differential travel
Sensing object
Standard sensing object
Response frequency
Power supply voltage (op-
erating voltage range) *1
Leakage current
Control
output
Indicators
Operation mode
(with sensing object ap-
proaching)
Ambient temperature *1, 2
Ambient humidity
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
(destruction)
Shock resistance
(destruction)
Degree of protection
Connection method
Weight (packed state)
Materi-
als
Accessories
to 200 mA max.
Load current *2
Residual voltage Refer to Engineering Data on page 5.
Case
Sensing surface PBT
Clamping nuts
Toothed washer Zinc-plated iron
http://www.ia.omron.com/
Shielding
Model
Size
2 mm±10%
0 to 1.6 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on
page 5.)
Iron,
12 × 12 × 1 mm
25 Hz
24 to 240 VAC (20 to 264 VAC), 50/60 Hz
1.7 mA max.
5 to 200 mA
Operation indicator (red)
Y1 Models: NO
Y2 Models: NC
Operating/Storage: −40 to 85°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C,
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
4,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
1,000 m/s
IEC IP67, in-house standard for oil resistance
Pre-wired Models (Standard cable length: 2 m) and Connector Models
Approx. 65 g
Brass
Nickel-plated brass
Instruction sheet
E2E2-X2Y@
Shielded
2
10 times each in X, Y, and Z directions
M12
Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
5 mm±10%
0 to 4 mm
Iron,
15 × 15 × 1 mm
E2E2-X5MY@
Unshielded
5 mm±10%
0 to 4 mm
Iron,
18 × 18 × 1 mm
5 to 300 mA
Approx. 150 g
E2E2-X5Y@
Shielded
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
M18
10 mm±10%
0 to 8 mm
Iron,
30 × 30 × 1 mm
E2E2-X10MY@
Unshielded
10 mm±10%
0 to 8 mm
Iron,
30 × 30 × 1 mm
Approx. 210 g
E2E2-X10Y@
Shielded
M30
18 mm±10%
0 to 14 mm
Iron,
54 × 54 × 1 mm
E2E2-X18MY@
Unshielded
E2E2
4