PKM4119CPINB Ericsson Power Modules, PKM4119CPINB Datasheet

DC/DC Converters & Regulators 2.5 Vdc 55A Iso Input 36-75V 137.5W

PKM4119CPINB

Manufacturer Part Number
PKM4119CPINB
Description
DC/DC Converters & Regulators 2.5 Vdc 55A Iso Input 36-75V 137.5W
Manufacturer
Ericsson Power Modules
Series
PKM-Cr
Datasheet

Specifications of PKM4119CPINB

Product
Isolated
Output Power
30 W
Input Voltage Range
36 V to 75 V
Number Of Outputs
1
Output Voltage (channel 1)
1.5 V
Output Current (channel 1)
20 A
Isolation Voltage
1.5 KV
Package / Case Size
Quarter Brick
Output Type
Isolated
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
E
Contents
General Information
Safety Specification
Absolute Maximum Ratings
2.5V, 55A / 137.5W Electrical Specification
3.3V, 50A / 165W Electrical Specification
12.0V, 17A / 204W Electrical Specification
EMC Specification
Operating Information
Thermal Consideration
Connections
Mechanical Information
Soldering Information
Delivery Information
Product Qualification Specification
Prepared (also subject responsible if other)
Prepared (also subject responsible if other)
SEC/D Kevin Zhou
SEC/S Kevin Zhou
Approved
Approved
SEC/D Kevin Zhou
SEC/D (Julia You)
PKM 4000C PINB series Direct Converters
Input 36-75 V, Output 55 A/204 W
Key Features
• Industry standard quarter-brick and optional double
• High efficiency, typ. 94 % at 12 Vout half load
• 2250 Vdc input to output isolation
• Meets isolation requirements equivalent to basic
• More than 2.7 million hours MTBF
General Characteristics
• Over temperature protection
• Over current limit protection
• Over voltage protection
• Remote control
• Output voltage adjust function
• Highly automated manufacturing ensures quality
• ISO 9001/14001 certified supplier
Product Program
Pin-Out. 57.9 x 36.8 x 9.35 mm (2.28 x 1.45 x 0.37 in.)
insulation according to IEC/EN/UL 60950
PKM4119C PINB .................................. 5
PKM4110C PINB .................................. 8
PKM4213C PINBSP ........................... 11
............................................................. 2
............................................................. 3
............................................................. 4
........................................................... 14
........................................................... 15
........................................................... 16
........................................................... 17
........................................................... 18
........................................................... 22
........................................................... 22
........................................................... 23
Ordering No.
Checked
Checked
MICOSPE
Public
Ericsson Internal
PRODUCT SPECIFICATION
TABLE OF CONTENTS
No.
No.
1/1301-BMR63701
001 52- EN/LZT 146 307 Uen
Date
Date
2007-1-29
8/19/2009
Safety Approvals
Technical Specifi cation
EN/LZT 146 307 R4B August 2009
© Ericsson Power Modules AB
Rev
H
Rev
F
Design for Environment
Meets requirements in high-
temperature lead-free soldering
processes.
Reference
Reference
1 (3)
1 (1)

Related parts for PKM4119CPINB

PKM4119CPINB Summary of contents

Page 1

... PKM4119C PINB .................................. 5 PKM4110C PINB .................................. 8 PKM4213C PINBSP ........................... 11 ........................................................... 14 ........................................................... 15 ........................................................... 16 ........................................................... 17 ........................................................... 18 ........................................................... 22 ........................................................... 22 ........................................................... 23 Technical Specifi cation Rev Reference Rev Reference EN/LZT 146 307 R4B August 2009 F H © Ericsson Power Modules AB Design for Environment Meets requirements in high- temperature lead-free soldering processes. 1 (3) 1 (1) ...

Page 2

... Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Limitation of Liability Ericsson power Modules does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person’ ...

Page 3

... Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. 48 and systems If the input voltage to Ericsson Power Modules DC/DC converter is 75 Vdc or less, then the output remains SELV (Safety Extra Low Voltage) under normal and abnormal operating conditions. ...

Page 4

... Checked Date (EBAOCMA) 2006-12-20 Positive logic option Negative logic Isolated Feedback Primary Secondary Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 A © Ericsson Power Modules AB min typ -40 -55 -0.5 -0.5 -0.5 -0.5 Voltage Control Monitoring 1 (5) 4 max ...

Page 5

... 0-100 +25° ref max must not be exceeded O Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 D © Ericsson Power Modules AB PKM 4119C PINB min typ max 5.7 0 137.5 55 91.5 88 89.2 91.7 88.9 18.8 2.6 100 180 200 220 2 ...

Page 6

... V 1 0,5 0,0 55,0 Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 D © Ericsson Power Modules [A] Dissipated power vs. load current and input voltage +25°C ref 0,5 1,0 1,5 2,0 2,5 Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section ...

Page 7

... By mounting PKM4000C in this way thermal derating can be improved by more than 10°C . Rev Reference EN/LZT 146 307 R4B August 2009 D © Ericsson Power Modules AB PKM 4119C PINB Place your graph here at: Top trace: output voltage (1 V/div.). I Bottom trace: input voltage (20 V/div.). ...

Page 8

... 0-100 +25° ref max must not be exceeded O Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 B © Ericsson Power Modules AB PKM 4110C PINB min typ max 5.7 0 165 50 92.2 89 90.3 92.3 90.1 20.4 3.4 100 145 155 165 3 ...

Page 9

... Thermal consideration section. [V] 4 1,0 0,0 50,0 O Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 B © Ericsson Power Modules +25°C ref 0,5 1,0 1,5 2,0 2,5 55,0 60,0 ...

Page 10

... By mounting PKM4000C in this way thermal derating can be improved by more than 10°C . Rev Reference EN/LZT 146 307 R4B August 2009 B © Ericsson Power Modules AB PKM 4110C PINB Place your graph here at: Top trace: output voltage (1 V/div.). I Bottom trace: input voltage (20 V/div.). ...

Page 11

... 0-100 +25° ref max must not be exceeded O Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 D © Ericsson Power Modules AB PKM 4213C PINBSP min typ max 5.7 0 204 61 94.2 92 93.4 94.4 93.3 17.7 2.8 100 180 200 220 11 ...

Page 12

... 3,0 0,0 18,0 [A] 17,0 O Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 D © Ericsson Power Modules AB 3,0 6,0 9,0 12,0 15,0 18,0 [A] = +25°C ref 0,5 1,0 1,5 2,0 2,5 19,0 21,0 23,0 25,0 27,0 [A] utput voltage vs. load current at I > ...

Page 13

... No. 2/1301-BMR 637 01/57 Uen Technical Specifi cation Checked Date Rev EN/LZT 146 307 R4B August 2009 (MICJAKE) 2006-06-20 D © Ericsson Power Modules AB Shut-down Shut-down enabled by disconnecting +25° ref O Output Load Transient Response Output voltage response to load current step- change (4.25-12.75-4.25 A) at: T =+25° ...

Page 14

... See Design Note 022 for detailed information. Filter components 0.68 μF C2,3 = 1.0 μF C4,5 = 2.2 nF C6,7 = 100 uF L1,2 = 0.768 mH Output ripple and noise test setup Technical Specifi cation EN/LZT 146 307 R4B August 2009 C © Ericsson Power Modules AB 14 ...

Page 15

... Vadj pin and +Sense pin. The resistor value of the Output voltage adjust function is according to information given under the output section. Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 C © Ericsson Power Modules AB ) adj 15 ...

Page 16

... Pcb 1 P Mosfet 2 P Mosfet 3 P Transformer 4 Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 C © Ericsson Power Modules AB +90°C. ref Designation max value T 110º C ref Tsurface 120º C Tsurface 120º C Tsurface 130º ...

Page 17

... Pin 4, 8,9 Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 C © Ericsson Power Modules AB Top View Designation Function +In Positive input RC Remote control - In Negative input - Out Negative output - Sen Negative remote sense Vadj Output voltage adjust ...

Page 18

... PKM 4000C PINB series Direct Converters Input 36-75 V, Output 55 A/204 W Mechanical Drawing for Single Pin out PRODUCT SPECIFICATION No. 4/1301-BMR 637 01 Uen Checked Date 2006-10-30 Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 C © Ericsson Power Modules AB 1 (7) 18 ...

Page 19

... PKM 4000C PINB series Direct Converters Input 36-75 V, Output 55 A/204 W Mechanical Drawing for Double Pin out PRODUCT SPECIFICATION No. 4/1301-BMR 637 01 Uen Checked Date 2006-10-30 Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 C © Ericsson Power Modules AB 2 (7) 19 ...

Page 20

... PKM 4000C PINB series Direct Converters Input 36-75 V, Output 55 A/204 W Mechanical Drawing for Base plate option with Single Pin out PRODUCT SPECIFICATION No. 4/1301-BMR 637 01 Uen Checked Date 2006-10-30 Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 C © Ericsson Power Modules AB 3 (7) 20 ...

Page 21

... PKM 4000C PINB series Direct Converters Input 36-75 V, Output 55 A/204 W Mechanical Drawing for Base plate option with Double Pin out PRODUCT SPECIFICATION No. 4/1301-BMR 637 01 Uen Checked Date 2006-10-30 Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 C © Ericsson Power Modules AB 4 (7) 21 ...

Page 22

... Box capacity 20 products (1 full tray/box) Tray weight 100 g empty, 1400 g full maximum PRODUCT SPECIFICATION No. 4/1301-BMR 637 01 Uen Checked Date 2006-10-30 12 Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 C © Ericsson Power Modules AB 5 (7) 22 ...

Page 23

... Tensile force Preconditioning Temperature, SnPb Eutectic Frequency Spectral density Duration Technical Specifi cation Rev Reference EN/LZT 146 307 R4B August 2009 C © Ericsson Power Modules AB -40 to +100 °C 300 30 min/0-1 min -40° +85 ° 1000 hours +125 °C 1000 h +90 ° +55 ± ...

Related keywords