PKM4119CPINB Ericsson Power Modules, PKM4119CPINB Datasheet - Page 14

DC/DC Converters & Regulators 2.5 Vdc 55A Iso Input 36-75V 137.5W

PKM4119CPINB

Manufacturer Part Number
PKM4119CPINB
Description
DC/DC Converters & Regulators 2.5 Vdc 55A Iso Input 36-75V 137.5W
Manufacturer
Ericsson Power Modules
Series
PKM-Cr
Datasheet

Specifications of PKM4119CPINB

Product
Isolated
Output Power
30 W
Input Voltage Range
36 V to 75 V
Number Of Outputs
1
Output Voltage (channel 1)
1.5 V
Output Current (channel 1)
20 A
Isolation Voltage
1.5 KV
Package / Case Size
Quarter Brick
Output Type
Isolated
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
EMC Specification
Conducted EMI measured according to EN55022, CISPR 22
and FCC part 15J (see test set-up).
The fundamental switching frequency is 200 kHz for
PKM 4211C PINB @ V
Conducted EMI Input terminal value (typ)
EMI without filter
External filter (class B)
Required external input filter in order to meet class B in
EN 55022, CISPR 22 and FCC part 15J.
EMI with filter
SEC/D (Julia You)
PKM 4000C PINB series Direct Converters
Input 36-75 V, Output 55 A/204 W
I
= 53 V, max I
O
.
Filter components:
C1 = 0.68 μF
C2,3 = 1.0 μF
C4,5 = 2.2 nF
C6,7 = 100 uF
L1,2 = 0.768 mH
EYINGJI
2007-12-10
Test set-up
Layout recommendation
The radiated EMI performance of the DC/DC converter will
depend on the PCB layout and ground layer design. It is also
important to consider the stand-off of the DC/DC converter.
If a ground layer is used, it should be connected to the output
of the DC/DC converter and the equipment ground or
chassis.
A ground layer will increase the stray capacitance in the PCB
and improve the high frequency EMC performance.
Output ripple and noise
Output ripple and noise measured according to figure below.
See Design Note 022 for detailed information.
Output ripple and noise test setup
Technical Specifi cation
EN/LZT 146 307 R4B August 2009
© Ericsson Power Modules AB
C