LAN9311-NU SMSC, LAN9311-NU Datasheet - Page 233

IC ETHER SW 2PRT 16BIT 128-VTQFP

LAN9311-NU

Manufacturer Part Number
LAN9311-NU
Description
IC ETHER SW 2PRT 16BIT 128-VTQFP
Manufacturer
SMSC
Type
Two Port Managed Ethernet Switchr
Datasheets

Specifications of LAN9311-NU

Controller Type
Ethernet Switch Controller
Interface
Serial EEPROM
Voltage - Supply
3.3V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
128-TQFP, 128-VQFP
Product
Ethernet Switches
Number Of Transceivers
1
Standard Supported
802.3, 802.3u
Data Rate
10 MB, 100 MB
Supply Voltage (max)
3.3 V
Supply Voltage (min)
0 V
Maximum Operating Temperature
+ 70 C
Ethernet Connection Type
10 Base-T, 100 Base-TX
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
For Use With
638-1076 - EVALUATION BOARD LAN9311-NU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
638-1075

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9311-NU
Manufacturer:
CINCERA
Quantity:
3 023
Part Number:
LAN9311-NU
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
LAN9311-NU
Manufacturer:
SMSC
Quantity:
20 000
Two Port 10/100 Managed Ethernet Switch with 16-Bit Non-PCI CPU Interface
Datasheet
SMSC LAN9311/LAN9311i
Note 14.8 The default value of this field is determined by the BP_EN_strap_2 configuration strap. The
Note 14.9 The default value of this bit is determined by multiple strap settings. The strap values are
Note 14.10 The default value of this field is determined by the FD_FC_strap_2 configuration strap. The
Note 14.11 The default value of this field is determined by the manual_FC_strap_2 configuration strap.
strap values are loaded during reset and can be re-written by the EEPROM Loader. Once
the EEPROM Loader re-writes the values, this register is updated with the new values.
See
loaded during reset and can be re-written by the EEPROM Loader. Once the EEPROM
Loader re-writes the values, this register is updated with the new values. Refer to
6.2.3, "Flow Control Enable Logic," on page 58
strap values are loaded during reset and can be re-written by the EEPROM Loader. Once
the EEPROM Loader re-writes the values, this register is updated with the new values.
See
The strap values are loaded during reset and can be re-written by the EEPROM Loader.
Once the EEPROM Loader re-writes the values, this register is updated with the new
values. See
Section 4.2.4, "Configuration Straps," on page 40
Section 4.2.4, "Configuration Straps," on page 40
Section 4.2.4, "Configuration Straps," on page 40
DATASHEET
233
for additional information.
for more information.
for more information.
for more information.
Revision 1.7 (06-29-10)
Section

Related parts for LAN9311-NU