H3DE-S2 AC/DC24-230 Omron Automation, H3DE-S2 AC/DC24-230 Datasheet - Page 2

no-image

H3DE-S2 AC/DC24-230

Manufacturer Part Number
H3DE-S2 AC/DC24-230
Description
Timer, Standard Type, DPDT, Analog, 0.1 Second to 120 Hours, 24-230 VAC/VDC
Manufacturer
Omron Automation
Datasheet

Specifications of H3DE-S2 AC/DC24-230

Brand/series
H3DE
Contact Form
DPDT
Current, Rating
5 A
Function
Timing
Mounting Type
DIN Rail
Relay Type
Electro Mechanical
Timer Type
Multi-Function
Voltage, Control
230 VAC/VDC
Voltage, Rating
250/30 VAC/VDC
Supply Voltage
24-230 VAC/VDC
Control Output
SPDT Time Limit (M1/S1), DPDT Time Limit SPDT and Instantaneous SPDT (M2/S2)
Lead Free Status / Rohs Status
RoHS Compliant part
Specifications
J GENERAL
Note: Can be mounted to 35-mm DIN track with a plate thickness of 1 to 2.5 mm.
J TIME RANGES
Note: When the main dial is set to “0” for all settings, the output will operate instantaneously.
J RATINGS
Note: 1. DC ripple rate: 20% max.
2
Item
Operating mode
Terminal block
Terminal screw tightening
torque
Input type
Output type
Mounting method
Attachment
Approved standards
Time scale display
x 0.1
x 1
Rated supply voltage
(See Notes 1 and 2.)
Operating voltage range
Power reset
Reset voltage
Power
consumption
(S
(See Note 3.)
Voltage input
Control output
Ambient temperature
Ambient humidity
2. Since an inrush current of 0.25 A will occur when using the power supply voltage at 24 VDC, pay careful attention when turning
3. The power consumption is for mode A (ON-delay) after the Timer counts the time-up time and for the AC input at 50 Hz. The
N t 3 )
p
on or off the power supply to the Timer with a solid-state output such as a sensor.
power consumption of the H3DE-Mj includes the input circuit with the B1 and A1 terminals short-circuited.
H3DE-M1
H3DE-M2
H3DE-S1
H3DE-S2
Time unit display
seconds
0.1 to 1.2 s
1 to 12 s
H3DE-M2
A: ON-delay (Signal or Power)
B: Repeat-cycle OFF start (Signal or Power)
B2: Repeat-cycle ON start (Signal or Power)
C: Signal ON-/OFF-delay
D: Signal OFF-delay
E: Interval (Signal or Power)
G: Signal ON-/OFF-delay
J: One-shot (Signal or Power)
Clamps two 2.5 mm
0.98 N S m max. {approx. 10 kgf S cm max.}
Voltage input
Relay: DPDT
DIN track mounting (See Note.)
Nameplate
UL508, CSA 22.2 No.14
Conforms to EN61812-1, IEC60664-1 (VDE0110) 4 kV/2, VDE0106/P100
Output category according to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)
24 to 230 VAC/DC (50/60 Hz)
12 VDC (H3DE-M2 model only)
85% to 110% of rated supply voltage
Minimum power-off time: 0.1 s
2.4 VAC/DC max.
AC: approx. 4.3 VA (2.2 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
AC: approx. 4.8 VA (2.4 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
AC: approx. 2.7 VA (1.6 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
AC: approx. 3.2 VA (1.9 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
Max. permissible capacitance between input lines (terminals B1 and A2) : 2000 pF
Load connectable in parallel with inputs (terminals B1 and A2)
H-level: 20.4 to 253 VAC/DC
L-level: 0 to 2.4 VAC/DC
Contact output: 5 A at 250 VAC with resistive load (cosφ = 1); 5 A at 30 VDC with resistive
load (cosφ = 1)
Operating: - -10°C to 55°C (14 to 131°F) with no icing
Storage: - -25°C to 65°C (- -13°F to 149°F) with no icing
Operating: 35% to 85%
2
max. bar terminals without sleeves.
min
0.1 to 1.2 min
1 to 12 min
H3DE-M1
Relay: SPDT
hrs
0.1 to 1.2 h
1 to 12 h
H3DE-S2
A: ON-delay
B2: Repeat-cycle ON start
E: Interval
J: One-shot
---
Relay: DPDT
10 h
1 to 12 h
10 to 120 h
H3DE-S1
Relay: SPDT

Related parts for H3DE-S2 AC/DC24-230