PIC16LF1827-E/SO Microchip Technology Inc., PIC16LF1827-E/SO Datasheet - Page 262

no-image

PIC16LF1827-E/SO

Manufacturer Part Number
PIC16LF1827-E/SO
Description
18 PIN, 7 KB FLASH, 384 BYTES RAM, 32 MHZ INT. OSC, 16 I/0, ENHANCED MID RANGE C
Manufacturer
Microchip Technology Inc.
Datasheet

Specifications of PIC16LF1827-E/SO

A/d Inputs
12-Channel, 10-Bit
Comparators
2
Cpu Speed
8 MIPS
Eeprom Memory
256 Bytes
Input Output
16
Interface
I2C/SPI/UART/USART
Memory Type
Flash
Number Of Bits
8
Package Type
18-pin SOIC
Programmable Memory
7K Bytes
Ram Size
384 Bytes
Speed
32 MHz
Temperature Range
–40 to 125 °C
Timers
4-8-bit, 1-16-bit
Voltage, Range
1.8-5.5 V
Lead Free Status / Rohs Status
RoHS Compliant part
PIC16(L)F1826/27
25.6
Master mode is enabled by setting and clearing the
appropriate SSPxM bits in the SSPxCON1 register and
by setting the SSPxEN bit. In Master mode, the SDAx
and SCKx pins must be configured as inputs. The
MSSP peripheral hardware will override the output
driver TRIS controls when necessary to drive the pins
low.
Master mode of operation is supported by interrupt
generation on the detection of the Start and Stop con-
ditions. The Stop (P) and Start (S) bits are cleared from
a Reset or when the MSSPx module is disabled. Con-
trol of the I
or the bus is Idle.
In Firmware Controlled Master mode, user code
conducts all I
Stop bit condition detection. Start and Stop condition
detection is the only active circuitry in this mode. All
other communication is done by the user software
directly manipulating the SDAx and SCLx lines.
The following events will cause the SSPx Interrupt Flag
bit, SSPxIF, to be set (SSPx interrupt, if enabled):
• Start condition detected
• Stop condition detected
• Data transfer byte transmitted/received
• Acknowledge transmitted/received
• Repeated Start generated
DS41391D-page 262
Note 1: The MSSPx module, when configured in
I
2: When in Master mode, Start/Stop detec-
2
C MASTER MODE
2
C bus may be taken when the P bit is set,
I
ing of events. For instance, the user is not
allowed to initiate a Start condition and
immediately write the SSPxBUF register
to initiate transmission before the Start
condition is complete. In this case, the
SSPxBUF will not be written to and the
WCOL bit will be set, indicating that a
write to the SSPxBUF did not occur
tion is masked and an interrupt is gener-
ated when the SEN/PEN bit is cleared and
the generation is complete.
2
C Master mode, does not allow queue-
2
C bus operations based on Start and
25.6.1
The master device generates all of the serial clock
pulses and the Start and Stop conditions. A transfer is
ended with a Stop condition or with a Repeated Start
condition. Since the Repeated Start condition is also
the beginning of the next serial transfer, the I
not be released.
In Master Transmitter mode, serial data is output
through SDAx, while SCLx outputs the serial clock. The
first byte transmitted contains the slave address of the
receiving device (7 bits) and the Read/Write (R/W) bit.
In this case, the R/W bit will be logic ‘0’. Serial data is
transmitted 8 bits at a time. After each byte is transmit-
ted, an Acknowledge bit is received. Start and Stop
conditions are output to indicate the beginning and the
end of a serial transfer.
In Master Receive mode, the first byte transmitted con-
tains the slave address of the transmitting device
(7 bits) and the R/W bit. In this case, the R/W bit will be
logic ‘1’. Thus, the first byte transmitted is a 7-bit slave
address followed by a ‘1’ to indicate the receive bit.
Serial data is received via SDAx, while SCLx outputs
the serial clock. Serial data is received 8 bits at a time.
After each byte is received, an Acknowledge bit is
transmitted. Start and Stop conditions indicate the
beginning and end of transmission.
A Baud Rate Generator is used to set the clock fre-
quency output on SCLx. See
Rate Generator”
I
2
C MASTER MODE OPERATION
for more detail.
 2011 Microchip Technology Inc.
Section 25.7 “Baud
2
C bus will

Related parts for PIC16LF1827-E/SO