EPM9320RI208-20 Altera, EPM9320RI208-20 Datasheet - Page 21

EPM9320RI208-20

Manufacturer Part Number
EPM9320RI208-20
Description
Manufacturer
Altera
Datasheet

Specifications of EPM9320RI208-20

Family Name
MAX 9000
Memory Type
EEPROM
# Macrocells
320
Number Of Usable Gates
6000
Frequency (max)
100MHz
Propagation Delay Time
23ns
Number Of Logic Blocks/elements
20
# I/os (max)
132
Operating Supply Voltage (typ)
5V
In System Programmable
Yes
Operating Supply Voltage (min)
4.5V
Operating Supply Voltage (max)
5.5V
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
208
Package Type
RQFP
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EPM9320RI208-20
Manufacturer:
ALTERA
Quantity:
142
Part Number:
EPM9320RI208-20
Manufacturer:
ALTERA
0
Part Number:
EPM9320RI208-20
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EPM9320RI208-20N
Manufacturer:
ALTERA
Quantity:
3 327
Part Number:
EPM9320RI208-20N
Manufacturer:
ALTERA
0
Altera Corporation
By combining the pulse and shift times for each of the programming
stages, the program or verify time can be derived as a function of the TCK
frequency, the number of devices, and specific target device(s). Because
different ISP-capable devices have a different number of EEPROM cells,
both the total fixed and total variable times are unique for a single device.
Programming a Single MAX 9000 Device
The time required to program a single MAX 9000 device in-system can be
calculated from the following formula:
where: t
The ISP times for a stand-alone verification of a single MAX 9000 device
can be calculated from the following formula:
where: t
t
t
PR OG
VER
=
=
t
VPULSE
t
Cycle
f
t
Cycle
TCK
t
PROG
PPULSE
VER
VPULSE
PP ULSE
PTCK
VTCK
+
+
C ycle
--------------------------------
MAX 9000 Programmable Logic Device Family Data Sheet
Cyc le
------------------------------- -
= Programming time
= Sum of the fixed times to erase, program, and
= Number of TCK cycles to program a device
= TCK frequency
f
= Verify time
= Sum of the fixed times to verify the EEPROM cells
= Number of TCK cycles to verify a device
TC K
f
T CK
VTC K
verify the EEPROM cells
PTC K
21