TDA8932B NXP Semiconductors, TDA8932B Datasheet - Page 10

no-image

TDA8932B

Manufacturer Part Number
TDA8932B
Description
The TDA8932B is a high efficiency class-D amplifier with low power dissipation
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TDA8932BT
Manufacturer:
ST
0
Part Number:
TDA8932BT
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
TDA8932BT
Quantity:
20
Part Number:
TDA8932BTW
Manufacturer:
ST
0
Part Number:
TDA8932BTW
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Company:
Part Number:
TDA8932BTW
Quantity:
16
Part Number:
TDA8932BTW/N2
Manufacturer:
NXP
Quantity:
200
Part Number:
TDA8932BTW/N2
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
TDA8932BTW/N2118
Manufacturer:
NXP Semiconductors
Quantity:
1 876
NXP Semiconductors
TDA8932B_4
Product data sheet
8.4.5 Supply voltage protection
If the supply voltage drops below 10 V, the UnderVoltage Protection (UVP) circuit is
activated and the system will shut down directly. This switch-off will be silent and without
pop noise. When the supply voltage rises above the threshold level, the system is
restarted again after 100 ms.
If the supply voltage exceeds 36 V the OverVoltage Protection (OVP) circuit is activated
and the power stages will shut down. It is re-enabled as soon as the supply voltage drops
below the threshold level. The system is restarted again after 100 ms.
It should be noted that supply voltages > 40 V may damage the TDA8932B. Two
conditions should be distinguished:
An additional UnBalance Protection (UBP) circuit compares the positive analog supply
voltage (V
voltage difference between them exceeds a certain level. This level depends on the sum
of both supply voltages. The unbalance threshold levels can be defined as follows:
In a symmetrical supply the UBP is released when the unbalance of the supply voltage is
within 6 % of its starting value.
Table 6
Table 6.
Protection
OTP
OCP
WP
UVP
OVP
UBP
1. If the supply voltage is pumped to higher values by the TDA8932B application itself
2. If a supply voltage > 40 V is caused by other or external causes, then the TDA8932B
When the amplifier is completely shut down due to activation of the OCP because a
short-circuit to one of the supply lines is made, then during restart (after 100 ms) the
window protection will be activated. As a result the amplifier will not start until the
short-circuit to the supply lines is removed.
(see also
supply voltage will decrease and the TDA8932B is protected against any overstress.
will shut down, but the device can still be damaged since the supply voltage will
remain > 40 V in this case. The OVP protection is not a supply voltage clamp.
LOW-level threshold: V
HIGH-level threshold: V
shows an overview of all protection and the effect on the output signal.
DDA
Protection overview
) and the negative analog supply voltage (V
Section
Restart
When fault is removed
no
yes
yes
no
no
no
Rev. 04 — 18 December 2008
14.3), the OVP is triggered and the TDA8932B is shut down. The
P(th)(ubp)l
P(th)(ubp)h
<
>
8
8
5
3
V
V
HVPREF
HVPREF
Every 100 ms
yes
no
no
yes
yes
yes
SSA
) and is triggered if the
Class-D audio amplifier
TDA8932B
© NXP B.V. 2008. All rights reserved.
10 of 48