TLE 7263E Infineon Technologies, TLE 7263E Datasheet - Page 12

no-image

TLE 7263E

Manufacturer Part Number
TLE 7263E
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE 7263E

Packages
PG-DSO-36
Transceiver
High Speed CAN ISO 11898 - 5 / 1 x LIN2.0 / J2602
Voltage Regulator Output
200 mA + 200 mA
Watchdog
Window Watchdog
Quiescent Current (max.)
49 ?A (typ) Sleep Mode (5V on)
Standby Current
68 ?A (typ) Stop Mode (5V on)
4.3
In order to reduce the current consumption to a minimum, but still supply a wake-up
circuit periodically, the SBC offers a Sleep Mode with Cyclic Sense (see
mode is entered via SPI command, and turns-off the integrated bus transceivers and
respective termination, as well as the main voltage regulator. The High-Side switch is
turned-on according to the SPI timings setting for cyclic sense, as there is the cyclic
sense period and the on-time. Upon a voltage level change at the monitoring/wake-up
pins or by a CAN or LIN message the SBC Sleep Mode will be terminated and the SBC
Standby Mode will automatically be entered. The respective RxD pin of the transceiver
that generated the wake-up will be pulled low.
Figure 5
Data Sheet
MS2
SBC Sleep Mode with Cyclic Sense
0
SBC Active Mode
State Diagram “SBC Sleep Mode with Cyclic Sense”
MS1
0 / 1
0 / 1
MS0
µController SPI-Command:
- select „cyclic sense period“ via SPI Timing Bits
- select HS-Switch on-time via SPI „On-Time Bit“
- select SBC Sleep Mode via SPI Mode Bits
- window watchdog activation / deactivation via SPI
[can remain active as periodic reset timer]
Vcc1
ON
„sense period“
MS2
MS2
1
1
SBC Sleep Mode
HS cyclic sense
HS-Switch = OFF
HS-Switch = ON
MONx inputs
Initialization of
MS1
MS1
0
0
MS0
MS0
after „on-time“
0
0
1)
Vcc1
Vcc1
OFF
OFF
12
SBC Standby Mode
Vcc1
ON
transition caused by:
- event at MON1 - 3 inputs
- event at MON4 input
- CAN message
- LIN message
[SPI indicates source]
[only during HS-ON state]
switched into SBC Standby mode
1)
if initialization fails, device is
cyclic_sense_sleep_TLE7263
Rev. 1.70, 2009-09-30
Power Up
Start Up
Figure