TLE 7263E Infineon Technologies, TLE 7263E Datasheet - Page 15

no-image

TLE 7263E

Manufacturer Part Number
TLE 7263E
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE 7263E

Packages
PG-DSO-36
Transceiver
High Speed CAN ISO 11898 - 5 / 1 x LIN2.0 / J2602
Voltage Regulator Output
200 mA + 200 mA
Watchdog
Window Watchdog
Quiescent Current (max.)
49 ?A (typ) Sleep Mode (5V on)
Standby Current
68 ?A (typ) Stop Mode (5V on)
4.6
The SBC Stop Mode has the advantage of reducing the current consumption to a
minimum, while supplying the microcontroller with its quiescent current during its power
saving mode (“Stop”). This mode is entered via SPI command, and turns-off the
integrated bus transceivers and respective termination, but the main voltage regulator
remains active. The High-Side switch is turned-on according to the SPI timings setting
for cyclic sense, as there is the cyclic sense period and the on-time. A voltage level
change at the monitoring/wake-up pins will, in contrast to the behavior in Sleep Mode,
generate a pulse at the WKO pin that is monitored by the microcontroller, e.g. at an
external interrupt input. In case the wake-up event was a CAN or LIN message, the
respective RxD pin will be pulled low. (The microcontroller itself has to take care of
switching SBC modes after a wake-up event notification (see
Figure 8
Data Sheet
MS2
0
SBC Stop Mode with Cyclic Sense
SBC Active Mode
State Diagram “SBC Stop Mode with Cyclic Sense”
MS1
0 / 1
MS0
0 / 1
µController SPI-Command:
- select „cyclic sense period“ via SPI Timing Bits
- select HS-Switch on-time via SPI „On-Time Bit“
- select SBC Stop Mode via SPI Mode Bits
- window watchdog activation / deactivation via SPI
[„off“ once current consumption below threshold]
Vcc1
ON
“sense period“
MS2
MS2
1
1
HS Cyclic Sense
SBC Stop Mode
HS-Switch = OFF
HS-Switch = ON
MONx inputs
Initialization of
MS1
MS1
1
1
after „on-time“
MS0
MS0
1
1
1)
Vcc1
Vcc1
ON
ON
15
SBC Standby Mode
Vcc1
ON
wake event notification [to µC]:
- CAN msg. => RxD
- LIN msg. => RxD
- MONx => WKO
transition caused by:
- event at MON1 - 3 inputs
- event at MON4 input
- CAN message
- LIN message
[only during HS-ON state]
[SPI indicates source]
Figure
switched into SBC Standby mode
1)
if initialization fails, device is
cyclic_sense_stop_TLE7263
Rev. 1.70, 2009-09-30
LIN
CAN
8).)
Power Up
Start Up
(low)
(low)
TLE 7263E
Features