BTS 7751G Infineon Technologies, BTS 7751G Datasheet - Page 6

no-image

BTS 7751G

Manufacturer Part Number
BTS 7751G
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of BTS 7751G

Packages
P-DSO-28
Operating Range
4.8 - 42.0 V
Rds (on) (typ)
115.0 mOhm
Id(lim)
15.0 A
Iq (typ)
5.0 µA
Diagnosis
OT, OL Status Flag
Data Sheet
Open Load Detection
Open load is detected by voltage measurement in Off state. If the output voltage exceeds
a specified level the error flag is set with a delay.
Status Flag
The status flag output is an open drain output with Zener-diode which requires a pull-up
resistor, c.f. the application circuit on page 14. Various errors as listed in the table
“Diagnosis” are detected by switching the open drain output ST to low. Forward current
in the integrated body diode of the high-side switch may cause undefined voltage levels
at the corresponding status output. The open load detection can be used to detect a
short to Vs as long as both low-side switches are off and R
by BCR192W.
2
Flag
Normal operation;
identical with functional truth table
Open load at high-side switch 1
Open load at high-side switch 2
Overtemperature high-side switch1
Overtemperature high-side switch2
Overtemperature both high-side switches
Under voltage
Inputs:
0 = Logic LOW
1 = Logic HIGH
X = don’t care
Truth table and Diagnosis (valid only for the High-Side-Switches)
Outputs:
Z = Output in tristate condition
L = Output in sink condition
H = Output in source condition
X = Voltage level undefined
IH1
0
0
1
1
0
1
X
X
0
1
X
X
0
X
1
X
6
Inputs
X
IH2
0
1
0
1
X
X
0
1
X
X
0
1
0
1
X
SH1
L
L
H
H
Z
H
X
X
L
L
X
X
L
L
L
L
Outputs
Status:
1 = No error
0 = Error
OL
SH2
L
H
L
H
X
X
Z
H
X
X
L
L
L
L
L
L
is disconnected from 5V
1
ST Remarks
1
1
1
1
0
1
0
1
1
0
1
0
1
0
0
BTS 7751 G
stand-by mode
switch2 active
switch1 active
both switches
active
detected
detected
detected
detected
detected
detected
not detected
2003-03-06