IDT5V9885B Integrated Device Technology, Inc., IDT5V9885B Datasheet - Page 11

no-image

IDT5V9885B

Manufacturer Part Number
IDT5V9885B
Description
3.3V EEPROM PROGRAMMABLE CLOCK GENERATOR
Manufacturer
Integrated Device Technology, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IDT5V9885B-003PFI
Manufacturer:
IDT
Quantity:
2 351
Part Number:
IDT5V9885B-003PFI8
Manufacturer:
IDT
Quantity:
107
Part Number:
IDT5V9885B-006NLGI
Manufacturer:
MOTOROLA
Quantity:
4 601
Part Number:
IDT5V9885B-007NLGI
Manufacturer:
TDT
Quantity:
2 615
Part Number:
IDT5V9885B-007NLGI8
Manufacturer:
IDT
Quantity:
192
Part Number:
IDT5V9885BNLGI
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT5V9885BNLGI8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT5V9885BPFGI
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT5V9885BPFGI
Manufacturer:
IDT
Quantity:
20 000
Part Number:
IDT5V9885BPFGI8
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
IDT5V9885BPFI
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
PLL is programmed for fractional divide.
with TSSC > '0', SS_OFFSET = '0', and SD = '0' in order to prevent an unstable state in the modulator. The A[3:0] must be used and set to be greater than
'2' for a more accurate fractional divide.
IDT5V9885B
3.3V EEPROM PROGRAMMABLE CLOCK GENERATOR
The spread spectrum parameters such as the modulation frequency and profile will not be enabled nor will it have any impact on the PLL output when the
The following is an example of how to set the fractional divider.
Example
F
Solving for 350MHz using Eq.2 and Eq.3 with PLL0 and spread spectrum off,
350MHz = 20MHz * (M / D)
For better jitter performance, keep D as small as possible
350MHz * 2 = M = 35
Therefore, we have D = 1, M = 35 (N = 16, A = 2) for PLL0 with P = 1 on output bank4 resulting in 350MHz.
Solving for 168.75MHz with PLL1 and fractional divide enabled:
168.75MHz = 20MHz * (M / D)
168.75MHz * 2 = M = 16.875 or 33.75
The 33.75 value is chosen to achieve the highest VCO frequency possible. Next step is to figure out the setting for the fractional divide using Eq.3.
33.75 = 2*N + A + 1 + SS_OFFSET * 1/64
Integer value 33 can be determined by N and A, thus leaving 0.75 left to be solved.
2*N + A + 1 = 33
SS_OFFSET = 64 * 0.75 = 48
Therefore, we have D=1, M=33.75 (N=15, A=2, SS_OFFSET=48) for PLL1 with P=2 on an output bank resulting in 168.75MHz.
The fractional divider can be determined if it is needed by following the steps in the previous example. Note that the 5V9885B should not be programmed
IN
20MHz
= 20MHz, F
20MHz
P
OUT
P * 2
P
1 = 168.75MHz, F
P * 2
1
1
2
OUT
2 = 350MHz
11
INDUSTRIAL TEMPERATURE RANGE

Related parts for IDT5V9885B