s908ab32ag0cfue Freescale Semiconductor, Inc, s908ab32ag0cfue Datasheet - Page 208

no-image

s908ab32ag0cfue

Manufacturer Part Number
s908ab32ag0cfue
Description
M68hc08 Microcontrollers
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s908ab32ag0cfueR
Manufacturer:
FREESCALE
Quantity:
20 000
Timer Interface Module B (TIMB)
12.7.1 Wait Mode
12.7.2 Stop Mode
12.8 TIMB During Break Interrupts
Technical Data
208
The TIMB remains active after the execution of a WAIT instruction. In
wait mode the TIMB registers are not accessible by the CPU. Any
enabled CPU interrupt request from the TIMB can bring the MCU out of
wait mode.
If TIMB functions are not required during wait mode, reduce power
consumption by stopping the TIMB before executing the WAIT
instruction.
The TIMB is inactive after the execution of a STOP instruction. The
STOP instruction does not affect register conditions or the state of the
TIMB counter. TIMB operation resumes when the MCU exit stop mode
after an external interrupt.
A break interrupt stops the TIMB counter.
The system integration module (SIM) controls whether status bits in
other modules can be cleared during the break state. The BCFE bit in
the SIM break flag control register (SBFCR) enables software to clear
status bits during the break state. See
Register.
To allow software to clear status bits during a break interrupt, write a
logic one to the BCFE bit. If a status bit is cleared during the break state,
it remains cleared when the MCU exits the break state.
To protect status bits during the break state, write a logic zero to the
BCFE bit. With BCFE at logic zero (its default state), software can read
and write I/O registers during the break state without affecting status
bits. Some status bits have a two-step read/write clearing procedure. If
software does the first step on such a bit before the break, the bit cannot
change during the break state as long as BCFE is at logic zero. After the
break, doing the second step clears the status bit.
Timer Interface Module B (TIMB)
8.8.3 SIM Break Flag Control
MC68HC908AB32
Freescale Semiconductor
Rev. 1.1

Related parts for s908ab32ag0cfue