pca9541a NXP Semiconductors, pca9541a Datasheet - Page 7

no-image

pca9541a

Manufacturer Part Number
pca9541a
Description
2-to-1 I2c-bus Master Selector With Interrupt Logic And Reset
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
pca9541aBS/03
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
pca9541aBS/03
Quantity:
165
Part Number:
pca9541aD/01
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
pca9541aD/01
Quantity:
2 500
Part Number:
pca9541aPW
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
pca9541aPW
Quantity:
1 459
Part Number:
pca9541aPW/01
Manufacturer:
TSSOP-16
Quantity:
20 000
Part Number:
pca9541aPW/01
0
Part Number:
pca9541aPW/01Ј¬112
Manufacturer:
NXP
Quantity:
2 200
Part Number:
pca9541aPW/03112
Manufacturer:
NXP Semiconductors
Quantity:
1 860
NXP Semiconductors
8. Functional description
PCA9541A_3
Product data sheet
8.1 Device address
8.2 Command Code
Refer to
Following a START condition, the upstream master that wants to control the I
make a status check must send the address of the slave it is accessing. The slave
address of the PCA9541A is shown in
resistors are incorporated on the hardware selectable pins and they must be pulled HIGH
or LOW.
The last bit of the slave address defines the operation to be performed. When set to
logic 1 a read is selected, while logic 0 selects a write operation.
Remark: Reserved I
with:
Following the successful acknowledgement of the slave address, the bus master will send
a byte to the PCA9541A, which will be stored in the Command Code register.
The 2 LSBs are used as a pointer to determine which register will be accessed.
If the auto-increment flag is set (AI = 1), the two least significant bits of the Command
Code are automatically incremented after a byte has been read or written. This allows the
user to program the registers sequentially or to read them sequentially.
Fig 5.
Fig 6.
‘reserved for future use’ I
slave devices that use the 10-bit addressing scheme (1111 0XX)
During a read operation, the contents of these bits will roll over to 00b after the last
allowed register is accessed (10b).
Figure 1 “Block diagram of
Slave address
Command Code
2
C-bus addresses must be used with caution since they can interfere
Rev. 03 — 16 July 2009
2-to-1 I
2
C-bus addresses (1111 1XX)
0
1
2
fixed
0
C-bus master selector with interrupt logic and reset
1
PCA9541A”.
auto-increment
0
1
Figure
AI
A3
selectable
hardware
0
A2
5. To conserve power, no internal pull-up
0
A1
register number
B1
002aab391
A0 R/W
002aab390
B0
PCA9541A
© NXP B.V. 2009. All rights reserved.
2
C-bus or
7 of 41