tda5360uk NXP Semiconductors, tda5360uk Datasheet - Page 13

no-image

tda5360uk

Manufacturer Part Number
tda5360uk
Description
Pre-amplifier For Hard Disk Drive With Mr-read / Inductive Write Heads
Manufacturer
NXP Semiconductors
Datasheet
Philips Semiconductors
10.2
Fault conditions are indicated on the FLT pin (HIGH during write mode and LOW during read mode). The fault condition
is coded and stored in Reg. 07 for monitoring purposes. The fault code is cleared on power up, on system reset and on
writing to Reg.09
The FLT output is an open collector to an external resistor of 5Kohms connected to +5V.
Table 1: Fault Conditions
1998 July 30
Mode
Both
Read
Write
Both
Pre-Amplifier for Hard Disk Drive with
MR-Read / Inductive Write Heads
Fault Mode
Fault condition
No fault
Write current present
Fault code not used
Thermal Asperity detected
Read head open
No write current
Write Data frequency to low
Write head open
Write head shorted to GND
Rext open or short
Write to read head short
Low Vcc or Low Vee
Fault code not used
Illegal head address
Fault code not used
Temperature too high
140 C
13
FCOD3
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
FCOD2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
Objective Specification, Revision 2.2
FCOD1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
TDA5360
FCOD0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1

Related parts for tda5360uk