adum1300 Analog Devices, Inc., adum1300 Datasheet - Page 10

no-image

adum1300

Manufacturer Part Number
adum1300
Description
Triple-channel Digital Isolators
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adum1300ARWZ
Manufacturer:
AD
Quantity:
20 000
Company:
Part Number:
adum1300ARWZ
Quantity:
12 000
Part Number:
adum1300ARWZ-RL
Manufacturer:
CAVIUM
Quantity:
230
Part Number:
adum1300ARWZ-RL
Manufacturer:
ADI
Quantity:
2
Part Number:
adum1300ARWZ-RL
Manufacturer:
ADI
Quantity:
4
Part Number:
adum1300ARWZ-RL
Manufacturer:
ADI
Quantity:
20 000
Part Number:
adum1300BRW
Manufacturer:
AD
Quantity:
77
Part Number:
adum1300BRW
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum1300BRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum1300BRWZ-RL
Manufacturer:
AD
Quantity:
1 900
Part Number:
adum1300BRWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuM1300/ADuM1301
PACKAGE CHARACTERISTICS
Table 4.
Parameter
Resistance (Input-Output)
Capacitance (Input-Output)
Input Capacitance
IC Junction-to-Case Thermal Resistance, Side 1
IC Junction-to-Case Thermal Resistance, Side 2
1
2
REGULATORY INFORMATION
The ADuM130x have been approved by the organizations listed in Table 5.
Table 5.
1
2
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 6.
Device considered a 2-terminal device; Pins 1, 2, 3, 4, 5, 6, 7, and 8 shorted together and Pins 9, 10, 11, 12, 13, 14, 15, and 16 shorted together.
Input capacitance is from any input data pin to ground.
In accordance with UL1577, each ADuM130x is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 µA).
In accordance with DIN EN 60747-5-2, each ADuM130x is proof tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection
limit = 5 pC). A “*” mark branded on the component designates DIN EN 60747-5-2 approval.
UL
Recognized under 1577
component recognition program
Double insulation, 2500 V rms
isolation voltage
File E214100
Parameter
Rated Dielectric Insulation Voltage
Minimum External Air Gap (Clearance)
Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index) CTI
Isolation Group
2
1
1
1
CSA
Approved under CSA Component
Acceptance Notice #5A
Reinforced insulation per
CSA 60950-1-03 and IEC 60950-1,
400 V rms maximum working voltage
File 205078
Symbol
L(I01)
L(I02)
Symbol
R
C
C
θ
θ
I-O
I-O
I
JCI
JCO
Rev. C | Page 10 of 20
Value
2500
8.40 min
8.10 min
0.017 min mm
>175
IIIa
Min
Unit
V rms
mm
mm
V
VDE
Certified according to DIN EN 60747-5-2
(VDE 0884 Part 2): 2003-01
Basic insulation, 560 V peak
Complies with DIN EN 60747-5-2 (VDE 0884 Part 2):2003-01,
DIN EN 60950 (VDE 0805): 2001-12; EN 60950:2000
Reinforced insulation, 560 V peak
File 2471900-4880-0001
Typ
10
1.7
4.0
33
28
Conditions
1 minute duration
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Insulation distance through insulation
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
12
Max
Unit
pF
pF
°C/W
°C/W
2
Test Conditions
f = 1 MHz
Thermocouple located
at center of package
underside

Related parts for adum1300