adum1300 Analog Devices, Inc., adum1300 Datasheet - Page 11

no-image

adum1300

Manufacturer Part Number
adum1300
Description
Triple-channel Digital Isolators
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adum1300ARWZ
Manufacturer:
AD
Quantity:
20 000
Company:
Part Number:
adum1300ARWZ
Quantity:
12 000
Part Number:
adum1300ARWZ-RL
Manufacturer:
CAVIUM
Quantity:
230
Part Number:
adum1300ARWZ-RL
Manufacturer:
ADI
Quantity:
2
Part Number:
adum1300ARWZ-RL
Manufacturer:
ADI
Quantity:
4
Part Number:
adum1300ARWZ-RL
Manufacturer:
ADI
Quantity:
20 000
Part Number:
adum1300BRW
Manufacturer:
AD
Quantity:
77
Part Number:
adum1300BRW
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum1300BRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adum1300BRWZ-RL
Manufacturer:
AD
Quantity:
1 900
Part Number:
adum1300BRWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
DIN EN 60747-5-2 (VDE 0884 PART 2) INSULATION CHARACTERISTICS
Table 7.
Description
Installation Classification per DIN VDE 0110
Climatic Classification
Pollution Degree (DIN VDE 0110, Table 1)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b1
Input to Output Test Voltage, Method a
Highest Allowable Overvoltage (Transient Overvoltage, t
Safety-Limiting Values (Maximum value allowed in the event of a failure; also see Thermal
Derating Curve, Figure 3)
Insulation Resistance at T
This isolator is suitable for basic isolation only within the safety limit data. Maintenance of the safety data is ensured by protective circuits.
The * marking on packages denotes DIN EN 60747-5-2 approval for 560 V peak working voltage.
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
V
After Environmental Tests Subgroup 1
V
After Input and/or Safety Test Subgroup 2/3
V
Case Temperature
Side 1 Current
Side 2 Current
IORM
IORM
IORM
Figure 3. Thermal Derating Curve, Dependence of Safety Limiting
350
300
250
200
150
100
50
× 1.875 = V
× 1.6 = V
× 1.2 = V
0
0
Values with Case Temperature per DIN EN 60747-5-2
PR
PR
, t
, t
PR
m
m
, 100% Production Test, t
50
= 60 sec, Partial Discharge < 5 pC
= 60 sec, Partial Discharge < 5 pC
CASE TEMPERATURE (°C)
SIDE #1
S
, V
SIDE #2
IO
= 500 V
100
150
m
= 1 sec, Partial Discharge < 5 pC
TR
200
= 10 sec)
Rev. C | Page 11 of 20
RECOMMENDED OPERATION CONDITIONS
Table 8.
Parameter
Operating Temperature
Supply Voltages
Input Signal Rise and Fall Times
1
All voltages are relative to their respective ground.
See the DC Correctness and Magnetic Field Immunity section on Page 16
for information on immunity to external magnetic fields.
Symbol
V
V
V
V
T
I
I
R
S1
S2
S
1
IORM
PR
PR
TR
S
Characteristic
I–IV
I–III
I–II
560
1050
896
672
4000
150
265
335
>10
40/105/21
2
ADuM1300/ADuM1301
9
Symbol
T
V
A
DD1
, V
DD2
Min Max
–40 +105 °C
2.7
5.5
1.0
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
Unit
V
ms

Related parts for adum1300