CY8C41000-24LFXI CYPRESS [Cypress Semiconductor], CY8C41000-24LFXI Datasheet - Page 29

no-image

CY8C41000-24LFXI

Manufacturer Part Number
CY8C41000-24LFXI
Description
Manufacturer
CYPRESS [Cypress Semiconductor]
Datasheet
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 36V
and -40°C ≤ T
to 3.0V and -40°C ≤ T
25°C and are for design guidance only.
8.31 3.0V to 36V AC Characteristics of I2C SDA and SCL Pins
Document 001-00360 Rev. *A
F
T
T
T
T
T
T
T
T
T
Parameter
SCLI2C
HDSTAI2C
LOWI2C
HIGHI2C
SUSTAI2C
HDDATI2C
SUDATI2C
SUSTOI2C
BUFI2C
SPI2C
a. A Fast-Mode I2C-bus device can be used in a Standard-Mode I2C-bus system, but the requirement t
ns must then be met. This will automatically be the case if the device does not stretch the LOW period of the SCL
signal. If such device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA
line t
SCL line is released.
rmax
A
SCL Clock Frequency
Hold Time (repeated) START
Condition. After this period, the
first clock pulse is generated.
LOW Period of the SCL Clock
HIGH Period of the SCL Clock
Set-up Time for a Repeated
START Condition
Data Hold Time
Data Set-up Time
Set-up Time for STOP Condition
Bus Free Time Between a STOP
and START Condition
Pulse Width of spikes are
suppressed by the input filter.
≤ 85°C (referred to as 5V operation), 3.0V to 3.6V and -40°C ≤ T
+ t
SU;DAT
A
≤ 85°C (referred to as 2.7V operation), respectively. Typical parameters apply to 5V, 3.3V, and 2.7V at
Description
= 1000 + 250 = 1250 ns (according to the Standard-Mode I2C-bus specification) before the
PRELIMINARY
Conditions
Standard Mode
Min.
250
A
4.0
4.7
4.0
4.7
4.0
4.7
CY8C41123 and CY8C41223
0
0
≤ 85°C (referred to as 3.3V operation), or 2.5V
Max.
100
100
Min.
0.6
1.3
0.6
0.6
0.6
1.3
0
0
0
Fast Mode
a
SU;DAT
Max.
400
50
Page 29 of 36
≥ 250
Units
kHz
µs
µs
µs
µs
µs
ns
µs
µs
ns